首页 | 本学科首页   官方微博 | 高级检索  
     


New Equipment for Neuromuscular Transmission Monitoring: A Comparison of the TOF-Guard with the Myograph 2000
Authors:Hans Kirkegaard-Nielsen  Hans Søren Helbo-Hansen  Peter Lindholm  Henrik Stougaard Pedersen  Inge Krogh Severinsen  Michael Braüner Schmidt
Affiliation:(1) From the Department of Anesthesia and Intensive Care, Odense University Hospital, DK-5000 Odense C, Denmark
Abstract:Objective. The present study is to clarify whether the bias and limits of agreement of the TOF-Guard and the mechanomyograph differ from those of two mechanomyographs on contra lateral arms. Previous studies of the bias and limits of agreement between acceleromyographical (TOF-Guard®) and mechanomyographical measurements of neuromuscular transmission did not take the error introduced by using contra lateral arms into consideration. Methods. Fifty-two women undergoing gynecological surgery were anesthetized with midazolam, fentanyl, thiopental, halothane and nitrous oxide. Neuromuscular blockade was induced and maintained with atracurium. In 32 patients, neuromuscular monitoring was performed with a Myograph 2000® on one hand and a TOF-Guard® at the other (M/T group). In 20 patients, monitoring was performed with a Myograph 2000® at both hands (M/M group). Train-of-four stimulations were applied to the ulnar nerve at the wrist in both groups. Bias and limits of agreement between the contra lateral hands in each group were calculated as proposed by Bland and Altman. Results. When the TOF ratio was 0.25, TOF ratio bias and limits of agreement in the M/T group were 0.86 and 17.58 to –15.85, respectively. Corresponding values in the M/M group were –1.75 and 12.3 to –8.8. Bias in the M/T group decreased significantly to –8.1 when TOF ratio increased to 0.70, resulting in limits of agreement of 12.1 to –28.4. The corresponding values in the M/M group were bias 2.0 and limits of agreement 10.7 to –6.7. TOF-Guard® bias for onset time and time to 5% recovery of T1 (first twitch in TOF) were –19 s and –1.5 min, respectively; both values differed significantly from zero (P < 0.05). Taken together with the changing TOF-ratio bias during recovery in the M/T group, these results indicate different onset and recovery curves for the two monitoring devices. Conclusions. Due to wide limits of agreement and different recovery courses, acceleromyographic and mechanomyographic recordings of neuromuscular transmission cannot be used interchangeably. The substantial variation between simultaneous mechanomyographical recordings of neuromuscular transmission obtained in contra lateral arms suggests that this factor should be taken into account when studying new neuromuscular monitoring techniques using the two-arm technique.
Keywords:Monitoring: neuromuscular function  Monitoring: train-of-four  Monitoring: acceleromyography  Monitoring: mechanomyography  Equipment: TOF-Guard  Equipment: Myograph 2000  Neuromuscular relaxants: atracurium
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号