Biomechanical evaluation of spinal stability after disc injury in a porcine model |
| |
Authors: | I H Chen C I Huang L S Lee |
| |
Affiliation: | Department of Neurosurgery, Taipei Municipal Chung-Hsiao Hospital, Taiwan. |
| |
Abstract: | The biomechanical effects of disc injury on flexion-extension were investigated in nine fresh porcine functional spinal units. Under 12 N-m in extension and 6 N-m in flexion, the range of motion among intact specimens were 23.11 degrees -33.29 degrees (mean = 26.07 degrees , SD = 3.25 degrees ), which shifted to 28.04 degrees -38.46 degrees (mean = 31.69 degrees , SD = 3.50 degrees ) when discs were injured. Similarly, the neutral zones among intact and disc injured specimens were 4.88 degrees -12.75 degrees (mean = 9.32 degrees , SD = 2.60 degrees ) and 9.50 degrees -24.43 degrees (mean = 16.80 degrees , SD = 4.69 degrees ) respectively. To obviate the differences between tested specimens, the changes of neutral zone and the range of motion after disc injury were normalized and expressed as ratios as compared to the same items before disc injury. The neutral zone ratio ranged from 1.29 to 3.18 (mean = 1.87, SD = 0.55, p < 0.01). For range of motion, it ranged from 1.13 to 1.42 (mean = 1.22, SD = 0.09, p < 0.01). The change of flexibility coefficient, however, was statistically insignificant in either flexion or extension. The model presented defines the range of motion, the neutral zone as well as the flexibility coefficient under a specific load. It suggests that major spinal instability can be elicited by a minimum flexion-extension moment, as reflected by a profound change of the neutral zone, after disc injury. |
| |
Keywords: | |
|
|