摘    要:目的;比较三种不同直径人骨拉力螺钉的剪切和扭转性能。方法:新鲜青壮年尸体股骨骨干,经深冻后制成直径为4mm,5mm,6mm的人骨拉力螺钉,在材料试验机上分别对螺钉的光杆部和螺纹部行剪切强度及刚度测试,再行扭转破坏。结果:直径为4mm,5mm,6mm的拉力骨螺钉的光杆部的剪切强度分别是526N,1034N,1459N,其螺纹部的剪切强度分别是290N,505N,931N,同一直径人骨拉力螺钉的光杆部

关 键 词:皮质骨 骨拉力螺钉 生物力学

A BIOMECHANICAL STUDY ON THE PROPERTY OF DIFFERENT DIAMETER CORTICAL PULLING-SCREW OF HUMAN
Shi jin, Wang Xinhai, Onyang Jun, et al. A BIOMECHANICAL STUDY ON THE PROPERTY OF DIFFERENT DIAMETER CORTICAL PULLING-SCREW OF HUMAN[J]. Journal of Medical Biomechanics, 1999, 14(2): 79-81
Authors:Shi jin   Wang Xinhai   Onyang Jun   et al
Abstract:To compare the cutting and reversing property of there different diameter conicalpulling-screws. Methods: In the material experimental machine, the conical pulling-screws withtheir respective diameter of 4mm, 5mm, 6mm which had been deeply frozen from fresh cadavericfemur shaft of young adult, examine the cutting intensity and rigidity property of the smooth partsof screw and the saw tooth parts seperately, then the reversing and destorying. Rusultf The cuttingintensity of the smooth part of screws were respectively 526N, 1034N, 1459N, and of the saw-toothpart of screws were respectively 290N, 505N, 931N. There marked differences in the cutting intensityand rigidity between the smooth of screw were marked and the saw-tooth part, which are of thesame diameter. The differences were also significant with different diameters. The maximummoments of force among the 4mm-diameter, 5mm-diameter, 6mm-diameter pulling-screw were0.64Nm, 1.59Nm, 2.10Nm respectively.While the moments of force of pulling-screws with differentdiameters were siguificant diferent. Conclusiont The biomechanical property of the pulling-screwswith same diameters is different, and the property of those with different diameter was slgnificantdifferent.
Keywords:Cortical-bone   Pulling-screw   Biomechanics
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《医用生物力学》浏览原始摘要信息
点击此处可从《医用生物力学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号