Carbon dioxide analysers: accuracy,alarm limits and effects of interfering gases
Authors:Rolf Lauber  Bruno Seeberger  Alex Martin Zbinden
Affiliation:1. Institute for Anaesthesiology and Intensive Care, Section of Research, University Hospital, 3010, Bern, Switzerland
Abstract:
Six mainstream and twelve sidestream infrared carbon dioxide (CO2) analysers were tested for accuracy of the CO2 display value, alarm activation and the effects of nitrous oxide (N2O), oxygen (O2) and water vapour according to the ISO Draft International Standard (DIS) #9918. Mainstream analysers (M-type): Novametrix Capnogard 1265; Hewlett Packard HP M1166A (CO2module HP M1016A); Datascope Passport; Marquette Tramscope 12; Nellcor Ultra Cap N-6000; Heilige Vicom-sm SMU 611/612 ETC. Sidestream analysers: Brüel &; Kjaer Type 1304; Datex Capnomac II; Marquette MGA-AS; Datascope Multinex; Ohmeda 4700 OxiCap (all type S1: respiratory cycles not demanded); Biochem BCI 9000; Bruker BCI 9100; Dräger Capnodig and PM 8020; Criticare Poet II; Heilige Vicom-sm SMU 611/612 A-GAS (all type S2: respiratory cycles demanded). The investigations were performed with premixed test gases (2.5, 5, 10 vol%, error ?1% rel.). Humidification (37° C) of gases were generated by a Dräger Aquapor. Respiratory cycles were simulated by manually activated valves. All monitors complied with the tolerated accuracy bias in CO2 reading (≤ 12% or 4 mmHg of actual test gas value) for wet and dry test gases at all concentrations, except that the Marquette MGA-AS exceeded this accuracy limit with wet gases at 5 and 10 vol% CO2. Water condensed in the metal airway adapter of the HP M1166A at 37° C gas temperature but not at 3(P C. The Servomex 2500 (nonclinical reference monitor), Passport (M-type), Multinex (S1-type) and Poet II (S2-type) showed the least bias for dry and wet gases. Nitrous oxide and O2 had practically no effect on the Capnodig and the errors in the others were max. 3.4 mmHg, still within the tolerated bias in the DIS (same as above). The difference between the display reading at alarm activation and the set point was in all monitors (except in the Capnodig: bias 1.75 mmHg at 5 vol% CO2) below the tolerated limit of the DIS (difference ≤ 0.2 vol%). The authors conclude that the tested monitors are safe for clinical use (except those failing the DIS limits). The accuracy of the CO2-reading (average of mean absolute bias) is better in the M-type than in the S1- or S2- type analysers although no statistical (nor clinical) significant differences could be detected. Most manufacturers work with stricter limits than those proposed by the DIS.
Keywords:carbon dioxide: end-tidal, measurement, monitoring   measurement techniques: capnometry   monitoring: carbon dioxide
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号