摘    要:目的 基于近红外光谱(near infrared spectroscopy,NIR)技术,以芍药内酯苷、芍药苷、密度和固含物为质量控制指标,对摩罗丹水提液的浓缩过程进行快速检测,实现摩罗丹浓缩过程在线质量控制.方法 采集摩罗丹水提液浓缩过程的在线近红外光谱,并收集样本;基于HPLC、烘干法等理化仪器分析方法,测定摩罗丹...

关 键 词:近红外光谱  偏最小二乘  质量控制  摩罗丹  浓缩过程
收稿时间:2020/12/10 0:00:00

Multi-indicators Rapid Determination in Concentration Process of Moluodan Water Extration Liquid by Near-infrared Spectroscopy
WU Chunyan,DU Wenjun,ZHANG Weidong,TAO Lingyan.Multi-indicators Rapid Determination in Concentration Process of Moluodan Water Extration Liquid by Near-infrared Spectroscopy[J].The Chinese Journal of Modern Applied Pharmacy,2022,39(1):87-92.
Authors:WU Chunyan  DU Wenjun  ZHANG Weidong  TAO Lingyan
Institution:Taizhou Vocational College of Sciences & Technology, Taizhou 318020, China;Pharmacy Department, Jinhua Municipal Central Hospital, Jinhua 321000, China; College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310058, China
Abstract:OBJECTIVE Based on near infrared spectroscopy(NIR) spectroscopy technology, taking alibiflorin, paeoniflorin, density and soluble solid content as quality control indicators, to carry out rapid detection of Moluodan aqueous extract in the concentration process, so as to realize the on-line quality control of Moluodan concentration process.METHODS Collect the on-line NIR spectrum of Moluodan aqueous extract in the concentration process, and collect samples. Based on HPLC, drying method and other physical and chemical instrument analysis methods, the content of important indexes of Moluodan aqueous extract were determined. Then the NIR spectrum correction model of important indexes was established by using partial least square method. Finally, the performance of the correction model was verified, and the correction model was used to predict the changes of important indexes in the concentration process of Moluodan aqueous extract.RESULTS The correlation coefficients(R) of the established calibration models for alibiflorin, paeoniflorin, density and solid content were > 0.98, the R of the validation set was > 0.99, and the relative deviation of the validation set was < 7%.CONCLUSION NIR spectral analysis technology can realize the rapid detection of alibiflorin, paeoniflorin, density and solid content in the concentration process of Moluodan aqueous extract, and the results are accurate and reliable.
Keywords:near-infrared spectroscopy  partial least squares  quality control  Moluodan  concentration process