首页 | 本学科首页   官方微博 | 高级检索  
     

SPM5软件分析癫痫患者脑PET图像的应用研究
引用本文:宁艳丽,晋建华,张宏,田梅,姚琼,占宏伟,赵春雷,许唯,叶小娟,李晶. SPM5软件分析癫痫患者脑PET图像的应用研究[J]. 国际放射医学核医学杂志, 2007, 33(1): 26-29. DOI: 10.3760/cma.j.issn.1673-4114.2009.01.026
作者姓名:宁艳丽  晋建华  张宏  田梅  姚琼  占宏伟  赵春雷  许唯  叶小娟  李晶
作者单位:山西医科大学第一医院核医学科,太原,030001;浙江大学附属第二医院PET中心,杭州,310009;
摘    要:
Objective To investigate the value of statistical parametric mapping 5 (SPM5) and its parameter settings in analysis of PET imaging for epilepsy patients. Methods Seventeen epilepsy patients and seventeen controls were scanned with PET. The datns were analyzed using PET and SPM5 with qualitative and semiquantitative analysis, statistical analysis of the percentage (numbers of agent distribution decreasing in focus to brain) for different parameters combinations, which were value adjustment to contral-p and voxels-k. Results There was decreasing of agent distribution at temporal lobe in epilepsy patients detecting with PET; the T/NT of focus to cerebellum was 1.07±0.24, the T/NT of normal tissue in opposite side to cerebellum was 1.27±0.18, there was a significant difference (t=1.87, P<0.05). Dealing with SPM5, there was more significant decreasing of agent in regions 19, 21, 39 of temporal lobe, regions 7, 19, 31, 40, 47 of parietal lobe and occipital lobe in epilepsy patients. With different value of k, the percentage was (27±22)%, (29±24)%, (32±23)%, (35±27)%, (39±31)%respectively, there was not significant difference (F=0.59, P>0.05) ; for different value of p, the percentage was (42±30) %, (29±25) %, (26±21) % respectively, with a significant difference (F=3.60, P<0.05); there was linear regression in value adjustment to contral-p and the percentage(b=-18.24, t=2.57, P<0.05). Conclusions Semiquantitative analysis by SPM5, the setting of value adjustment to contral-p would affect the results, the smaller of value adjustment to contral-p, the better of the result. SPM5 would be more objective and accurate to locate the focuses.

关 键 词:癫痫   正电子发射体层摄影术   统计参数图5   

Application study of SPM5 in analysis of PET imaging for epilepsy patient
NING Yan-li,JIN Jian-hua,ZHANG Hong,TIAN Mei,YAO Qiong,LI Jing,ZHAN Hong-wei,ZHAO Chun-lei,XU Wei,YE Xiao-juan. Application study of SPM5 in analysis of PET imaging for epilepsy patient[J]. International Journal of Radiation Medicine and Nuclear Medicine, 2007, 33(1): 26-29. DOI: 10.3760/cma.j.issn.1673-4114.2009.01.026
Authors:NING Yan-li  JIN Jian-hua  ZHANG Hong  TIAN Mei  YAO Qiong  LI Jing  ZHAN Hong-wei  ZHAO Chun-lei  XU Wei  YE Xiao-juan
Abstract:
Keywords:EpilepsyPositron-emission tomographyStatistical parametric mapping 5
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号