Receiver operating characteristic curve analysis for image quality in the detection of solitary pulmonary nodules on high resolution paper prints versus dry laser film |
| |
Authors: | HU Xiao-yun FANG Xiang-ming CAO Yang HU Chun-hong YAO Xuan-jun CHEN Hong-wei HU Su |
| |
Affiliation: | HU Xiao-yun (Jiangsu Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Medical College of Soochow University, Suzhou, Jiangsu 215123, China;Imaging Center, Wuxi People's Hospital Affiliated to Nanjing Medical University, Wuxi, Jiangsu 214023, China);FANG Xiang-ming (Imaging Center, Wuxi People's Hospital Affiliated to Nanjing Medical University, Wuxi, Jiangsu 214023, China);CAO Yang (Department of Radiology, Wuxi Huishan People's Hospital, Wuxi,Jiangsu 214187, China);HU Chun-hong (Jiangsu Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Medical College of Soochow University, Suzhou, Jiangsu 215123, China);YAO Xuan-jun (Imaging Center, Wuxi People's Hospital Affiliated to Nanjing Medical University, Wuxi, Jiangsu 214023, China);CHEN Hong-wei (Imaging Center, Wuxi People's Hospital Affiliated to Nanjing Medical University, Wuxi, Jiangsu 214023, China);HU Su (Jiangsu Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Medical College of Soochow University, Suzhou, Jiangsu 215123, China); |
| |
Abstract: | Along with the development of digital X-ray imaging technology,a new,economical and practical paper-based output system gradually emerged.To reduce cost,more and more radiologic institutions began to change from film copies to lower-priced paper prints for documenting radiologic findings.1 Therefore,laser paper printers are frequently used as an alternative to duplicating film though the use of printed images is not yet widespread.The aim of this study was to compare the practical value of high-resolution paper printer with dry film copies for detecting small solitary pulmonary nodules (SPNs).METHODSClinical dataSixty cases (28 cases of SPN,others were negative) of patients for thoracic plain CT scans were deliberately selected by 2 senior doctors in consensus via workstation or picture archiving and communication system (PACS) regarded as a gold standard,and all nodules were confirmed by surgery or clinical follow-up.The diameters of nodules were in the range of 3-20 mm. |
| |
Keywords: | receiver operating characteristic paper printer solitary pulmonary nodule dry laser printer |
本文献已被 维普 等数据库收录! |
| 点击此处可从《中华医学杂志(英文版)》浏览原始摘要信息 |
|
点击此处可从《中华医学杂志(英文版)》下载全文 |
|