首页 | 本学科首页   官方微博 | 高级检索  
检索        


Beyond coronary sinus angiography: the value of coronary arteriography and identification of the pericardiophrenic vein during left ventricular lead placement
Authors:Vaseghi Marmar  Cesario David A  Ji Sen  Shannon Kevin M  Wiener Isaac  Boyle Noel G  Fonarow Gregg C  Valderrábano Miguel  Shivkumar Kalyanam
Institution:UCLA Cardiac Arrhythmia Center, Divisions of Cardiology, Department of Medicine, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095-1679, USA.
Abstract:OBJECTIVE: The purpose of this study was to define the role coronary arteriography (venous phase) for improving the success of left ventricular (LV) lead implantation and to define the value of identifying the pericardiophrenic vein for optimal LV lead placement in biventricular (bi-v) device implantation. METHODS: Seventy-seven patients underwent bi-v device implantation between July 2002 and October 2003. If the coronary sinus (CS) could not be accessed, then left coronary arteriography was performed during the same procedure. CS access was guided by venous phase images of the coronary arteriogram. The pericardiophrenic vein was identified by selective cannulation or direct visualization. Patients with Cr > 1.5 had gadolinium used as the contrast agent. RESULTS: Seventy-five successful implants were performed (97%). In seven patients (9%) repeated attempts at retrograde cannulation of the CS failed (attempt time 130 +/- 20 minute, mean +/- SD). In these patients, coronary arteriography helped define the location of the CS, which was subsequently successfully cannulated. In six patients the pericardiophrenic vein was identified either during occlusion venography of the CS (postthoracotomy, veno-venous collaterals, n = 2) or during selective cannulation of the pericardiophrenic vein (using a DAIG Csl catheter, n = 4). The vein was directly visualized in three patients who underwent surgical LV lead implantation. LV leads in all these cases were implanted in areas not overlying the preidentified pericardiophrenic vein. During follow-up, none of these patients had evidence of phrenic nerve stimulation. CONCLUSIONS: Intraoperative left coronary arteriography increases the success of CS cannulation. Identification of the pericardiophrenic vein is a useful method to avoid phrenic nerve stimulation.
Keywords:coronary sinus                        angiography                        gadolinium                        pericardiophrenic                        biventricular
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号