首页 | 本学科首页   官方微博 | 高级检索  
     

第三代双源CT在心律不齐冠脉CTA检查中的应用价值
引用本文:林列兴,陈羽. 第三代双源CT在心律不齐冠脉CTA检查中的应用价值[J]. 中国卫生标准管理, 2021, 0(2): 46-48
作者姓名:林列兴  陈羽
作者单位:福建省立医院放射科;福建省福州市第一医院放射科
摘    要:目的 探索第三代双源CT在心律不齐患者冠状动脉CT血管造影(CT angiography,CTA)扫描过程中的应用.方法 选择本院收治的心律不齐患者96例,随机分为对照组和观察组进行CTA扫描,各48例.对照组给予第一代双源CT上行常规CT技术进行检查,观察组给予第三代双源CT上行低管电压、低剂量碘造影剂的双低技术进行...

关 键 词:第三代双源CT  CTA检查  心律不齐  辐射剂量  信号噪声比  应用价值

Application Value of Third-generation Dual-source CT in CTA Examination of Arrhythmia Coronary Artery
LIN Liexing,CHEN Yu. Application Value of Third-generation Dual-source CT in CTA Examination of Arrhythmia Coronary Artery[J]. China Health Standard Management, 2021, 0(2): 46-48
Authors:LIN Liexing  CHEN Yu
Affiliation:(Department of Radiology,Fujian Provincial Hospital,Fuzhou Fujian 350001,China;Department of Radiology,Fuzhou First Hospital,Fuzhou Fujian 350009,China)
Abstract:Objective To explore the application of third-generation dualsource CT in coronary angiography(CT angiography,CTA)scanning in patients with arrhythmia.Methods 96 patients with arrhythmia admitted to our hospital were selected and randomly divided into a control group and an observation group for CTA scan,48 cases each.The control group was given the first-generation dual-source CT ascending conventional CT technique for examination,and the observation group was given the thirdgeneration dual-source CT ascending low tube voltage and low-dose iodine contrast agent for examination.Compare the subjective evaluation indexes(CT value,signal-to-noise ratio)of the two groups,observe and record the radiation dose and image quality.Results The objective evaluation of the image quality was completed between the two groups,the CT value of the aortic root,the noise(SD)and the signal-to-noise ratio(SNR)of the control group were not significantly higher than the observation group,the difference was not statistically significant(P>0.05).The DLP and ED values were statistically different(P<0.05),the subjective evaluation of the image quality of the two groups showed that the observation group scores(right coronary artery,left coronary artery trunk,left circumflex branch,left anterior descending branch)were significantly better than the control group,with statistical difference(P<0.05).Conclusion When performing CTA examination in patients with arrhythmia,the third-generation dual-source CT has high image quality,low radiation dose,and higher safety.
Keywords:third-generation dual-source CT  CTA examination  arrhythmia  radiation dose  signal-to-noise ratio  application value