锎-252的微观能量沉积
引用本文:郑文忠,唐明华,郭勇,孙沂清,史元明. 锎-252的微观能量沉积[J]. 中华放射医学与防护杂志, 1981, 1(5): 1-6
作者姓名:郑文忠  唐明华  郭勇  孙沂清  史元明
摘    要:


MICROSCOPIC ENERGY DEPOSITION FOR CAUFORNIUM-252
Zheng Wenzhong,Tang Minghu,Guo Yong,Sun Yiqing and Shi Yuanming. MICROSCOPIC ENERGY DEPOSITION FOR CAUFORNIUM-252[J]. Chinese Journal of Radiological Medicine and Protection, 1981, 1(5): 1-6
Authors:Zheng Wenzhong  Tang Minghu  Guo Yong  Sun Yiqing  Shi Yuanming
Abstract:The experiment is based on the principle of the microdosimetry.A spherical tissue equivalent proportional counter(LET-SW1/2)is filled to a pressure of 57.1 mmHg with the tissue equivalent gas(62.7%CH4,34% CO2,3.2% N2 and 0.1% O2 by vo-lume)to simulate the tissue diameter of one micron.We have measured the frequency distribution of event size P(Y)for californium-252 neutron source and computed the dose distribution of event size D(Y).The text described mainly the experiment method of the microdosimetry and the procedure of the data processing.