首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of copper(II)-pyruvaldehyde bis (N-4-methylthiosemicarbazone) for tissue blood flow measurement usina a trapped tracer model
Authors:Helen Young  Paul Carnochan  Jamal Zweit  John Babich  Simon Cherry  Robert Ott
Affiliation:(1) Joint Department of Physics, Royal Marsden Hospital and Institute of Cancer Research, Downs Road, SM2 5PT Sutton, Surrey, UK;(2) Present address: Division of Nuclear Medicine, Massachusetts General Hospital, 02114 Boston, MA, USA;(3) Present address: Division of Nuclear Medicine and Biophysics, UCLA School of Medicine, 90024 Los Angeles, CA, USA
Abstract:Copper(II)-pyruvaldehyde bis (N-4-methylthiosemicarbazone) (Cu-PTSM) labelled with 62,64Cu is a promising radiotracer for the study of blood flow using positron emission tomography (PET). We have investigated the application of a simple trapped tracer model to measurements of tissue 64Cu-PTSM uptake combined with continuous arterial sampling. A dual-tracer method was used to compare blood flow estimated by 64Cu-PTSM with values derived from measurements using cobalt-57 microspheres in the rat. Prolonged retention of 64Cu-PTSM following intravenous administration was initially confirmed in both normal tissues and tumours. After intraventricular 64Cu-PTSM infusion, cumulative arterial 64Cu activity increased progressively, and after extraction in n-octanol was found to plateau to levels corresponding with those reached following administration of 57CO microspheres. Rapid and species-dependent rates of 64Cu-PTSM decomposition to non-extractable 64Cu complexes were found in rat and human blood in vitro (70%±6% and 43%±5% respectively at 16 min), demonstrating the need for immediate processing of arterial samples. Close agreement was found between blood flow estimated by 64Cu-PTSM and 57CO microsphere methods in tissues of low to moderate flow: muscle (0.01, 0.08, 0.07 ml/min per gram; mean difference, mean 64Cu, mean 57Co), brain (0.09, 0.52, 0.43 ml/min per gram) and kidney (–0.16, 2.29, 2.45 ml/min per gram). Estimates of cardiac output also compared favourably between the two methods (5.7, 59.8, 54.1 ml/min). We conclude that a simple tissue trapping model may be suitable for the derivation of blood flow estimates using 62,64Cu-PTSM, PET imaging and continuous arterial blood sampling.Correspondence to: P. Carnochan
Keywords:Cu-PTSM  Blood flow  Microspheres  Arterial sampling
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号