首页 | 本学科首页   官方微博 | 高级检索  
     


Bond strengths of two conventional glass-ionomer cements to irradiated and non-irradiated dentin
Authors:Yesilyurt Cemal  Bulucu Bilinç  Sezen Orhan  Bulut Güneş  Celik Davut
Affiliation:Department of Operative Dentistry, Faculty of Dentistry, Karadeniz Technical University, Trabzon, Turkey. cyesilyurt@ktu.edu.tr
Abstract:
This study evaluated the influence of irradiation on the dentin shear bond strength of two conventional glass ionomer cements (GICs). Thirty extracted molars were bisected in the mesio-distal direction. One-half of 20 teeth were irradiated with 60 Gy (5 days/week) for 6 weeks, and then GIC was placed on the irradiated dentin surface (Groups A1, B1). For the other halves of these tooth specimens, the GICs were first placed on their dentin surfaces and then the specimens irradiated (Groups A2, B2). The remaining 10 teeth were bisected and used as non-irradiated controls (Groups C1, C2). The GIC-dentin shear bond strengths were examined. Groups A2 and B2 had significantly lower bond strengths than groups A1, B1, C1, and C2 (p < 0.05). No significant differences were found among groups A1, B1, C1, and C2 (p > 0.05). In conclusion, irradiation may have an adverse effect on the bond strength of GICs depending on the application sequence.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏