Diagnostic yield of high-density versus low-density EEG: The effect of spatial sampling,timing and duration of recording |
| |
Authors: | Anders Bach Justesen Mette Thrane Foged Martin Fabricius Christian Skaarup Nizar Hamrouni Terje Martens Olaf B. Paulson Lars H. Pinborg Sándor Beniczky |
| |
Affiliation: | 1. Department of Clinical Neurophysiology, Danish Epilepsy Centre, Dianalund, Denmark;2. Neurobiology Research Unit, Department of Neurology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark;3. Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark;4. Department of Clinical Neurophysiology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark;5. Epilepsy Clinic, Department of Neurology Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark;6. Department of Clinical Medicine, Aarhus University, Aarhus, Denmark;7. Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark |
| |
Abstract: | ObjectiveTo investigate the effect of spatial sampling and of recording duration on the diagnostic yield of EEG for identification of interictal epileptiform discharges (IEDs). Previous studies demonstrated that high-density (HD) recordings increased accuracy of localization compared to low-density (LD) recordings.MethodsWe have prospectively evaluated the effect of spatial sampling and of recording duration in patients who had short-term (ST) recordings with a HD array of 256 electrodes following long-term (LT) recordings with a LD array consisting of the standard IFCN array of 25 electrodes. IED clusters were identified in four datasets: LT-LD, ST-LD (spatially down-sampled to the standard IFCN array), ST-HD and a shortened (90 minutes) epoch of LT-LD.ResultsSixty consecutive patients were recruited. We identified 89 IED clusters totally. Two clusters were found by increasing spatial sampling from 25 to 256 electrodes. This modest increase was not statistically significant. Eight clusters were missed by reducing the recording duration to 90 minutes, as compared with the LT recordings (p = 0.003).ConclusionsRecording duration is more important for the diagnostic yield of EEGs than increasing spatial sampling beyond the standard IFCN electrode array.SignificanceThe standard IFCN electrode array provides sufficient spatial sampling for identification of the IEDs. |
| |
Keywords: | Corresponding author at: Visby Allé 5, 4293 Dianalund, Denmark. Fax: +45 58271188. Diagnostic yield Duration EEG High-density array Interictal epileptiform discharges Spatial sampling |
本文献已被 ScienceDirect 等数据库收录! |
|