首页 | 本学科首页   官方微博 | 高级检索  
     


Diagnostic yield of high-density versus low-density EEG: The effect of spatial sampling,timing and duration of recording
Authors:Anders Bach Justesen  Mette Thrane Foged  Martin Fabricius  Christian Skaarup  Nizar Hamrouni  Terje Martens  Olaf B. Paulson  Lars H. Pinborg  Sándor Beniczky
Affiliation:1. Department of Clinical Neurophysiology, Danish Epilepsy Centre, Dianalund, Denmark;2. Neurobiology Research Unit, Department of Neurology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark;3. Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark;4. Department of Clinical Neurophysiology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark;5. Epilepsy Clinic, Department of Neurology Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark;6. Department of Clinical Medicine, Aarhus University, Aarhus, Denmark;7. Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark
Abstract:
ObjectiveTo investigate the effect of spatial sampling and of recording duration on the diagnostic yield of EEG for identification of interictal epileptiform discharges (IEDs). Previous studies demonstrated that high-density (HD) recordings increased accuracy of localization compared to low-density (LD) recordings.MethodsWe have prospectively evaluated the effect of spatial sampling and of recording duration in patients who had short-term (ST) recordings with a HD array of 256 electrodes following long-term (LT) recordings with a LD array consisting of the standard IFCN array of 25 electrodes. IED clusters were identified in four datasets: LT-LD, ST-LD (spatially down-sampled to the standard IFCN array), ST-HD and a shortened (90 minutes) epoch of LT-LD.ResultsSixty consecutive patients were recruited. We identified 89 IED clusters totally. Two clusters were found by increasing spatial sampling from 25 to 256 electrodes. This modest increase was not statistically significant. Eight clusters were missed by reducing the recording duration to 90 minutes, as compared with the LT recordings (p = 0.003).ConclusionsRecording duration is more important for the diagnostic yield of EEGs than increasing spatial sampling beyond the standard IFCN electrode array.SignificanceThe standard IFCN electrode array provides sufficient spatial sampling for identification of the IEDs.
Keywords:Corresponding author at: Visby Allé 5, 4293 Dianalund, Denmark. Fax: +45 58271188.  Diagnostic yield  Duration  EEG  High-density array  Interictal epileptiform discharges  Spatial sampling
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏