首页 | 本学科首页   官方微博 | 高级检索  
     


Late results after left-sided cardiac valve replacement in children
Authors:A Milano  P R Vouhé  F Baillot-Vernant  P Donzeau-Gouge  F Trinquet  P M Roux  F Leca  J Y Neveux
Abstract:Selection of types of cardiac valve substitutes for children remains controversial. Between 1976 and 1984, 166 children, 15 years of age or younger, underwent aortic (N = 53) or mitral valve replacement (N = 90) or both (N = 23). Biological prostheses were used in 84 patients and mechanical prostheses in 71; both a mitral bioprosthesis and an aortic mechanical valve were used in 11 patients. The overall early mortality was 9%. Mean follow-up intervals were 4.1 years for the bioprosthesis group, 3.3 years for the mechanical valve group, and 3.5 years for the group receiving both. The 7 year survival rates (+/- standard error) were 63% +/- 6% in the bioprosthesis group and 70% +/- 7% in the mechanical valve group (p = NS). After aortic valve replacement the 7 year survival rates were 66% +/- 14% (bioprosthesis group) and 77% +/- 9% (mechanical valve group) (p = NS); after mitral valve replacement the rates were 65% +/- 7% (bioprosthesis group) and 54% +/- 17% (mechanical valve group) (p = NS). The incidence of thromboembolic events was 0.6% +/- 0.4% per patient-year in the bioprosthesis group (none after aortic valve replacement, 0.8% +/- 0.6% per patient-year after mitral valve replacement) and 1.4% +/- 0.8% per patient-year in the mechanical valve group (0.7% +/- 0.7% per patient-year after aortic valve replacement, 4.0% +/- 2.8% per patient-year after mitral valve replacement) (p = NS). The linearized rates of reoperation were 10.4% +/- 1.8% per patient-year (bioprosthesis group) and 2.3% +/- 1.0% per patient-year (mechanical valve group) (p less than 0.001). The 7 year probability rates of freedom from all valve-related complications were 43% +/- 6% in the bioprosthesis group and 86% +/- 4% in the mechanical valve group (p less than 0.001). In the aortic position, a mechanical adult-sized prosthesis can always be implanted, and satisfactory long-term results can be anticipated. In the systemic atrioventricular position, the results are less than satisfactory with either type of prosthesis; every effort should be made to preserve the natural valve of the child.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号