摘    要:
目的了解中山市2005--2007年度50家企业噪声危害的基本情况。方法采用队列研究的方法对噪声危害企业进行连续3年的噪声危害职业卫生现场调查和对接噪工人进行纯音听力测试。结果2005--2007年50家企业噪声监测点的合格率分别为3.9%、5.1%、5.6%。噪声监测其平均水平均超过GBZ1—2002(工业企业设计卫生标准》,按照LD80—1995(噪声作业分级》,为噪声中度危害。连续3年的纯音听力测试显示3年的总体异常率(高频+语频)差异无统计学意义(P〉0.05)。但连续3年的语频异常率差异有统计学意义(X^2=37.41,P〈0.01),高频差异无统计学意义(X^2=0.64,P〉0.05)。结论随着接噪时间的延长,特别是接噪时间超过3年以上,语频听力损伤率逐渐增高。

关 键 词:噪声  高频听力损失  语频听力损失

Investigation of the Noise Hazard in 50 Enterprises of Zhongshan City during 2005-2007
Affiliation:LIU Xin-xia ,HUANG Guo-xian , GUO Zhi-ping, et al. (Zhongshan Center for Disease Control and Prevention, Guangdong, 528400, China)
Abstract:
[ Objective ] To understand the basic situation of noise hazard in 50 enterprises of Zhongshan during 2005-2007. [ Methods] Array study method was used to conduct a continuous three years'occupational health field investigation on the noise hazard in the enterprises and pure sound hearing test among the noise-exposed workers. [ Results] The eligible rates in the three surveillance spots among the 50 enterprises during 2005-2007 were 3.9% , 5.1% and 5.6% respectively; the average level of noise surveillance exceeded the criteria according to GBZ 1-2002 Sanitary Criteria for Industrial Enterprise Design; the noise hazard belonged to the medium level according to LD80-1995 Noise-Exposure Classification ; no significant difference was found in the total abnormal rate ( high frequency and speech frequency) of the pure sound hearing test within the continuous three years ( P 〉0.05 ) ; but the difference was significant in the abnormal rate of speech frequency ( P 〈 0.01 ) and was not significant in that of the high frequency ( P 〉 0.05 ). [ Conclusion ] The speech frequency hearing loss increases along with the noise-exposure length, especially that over three years.
Keywords:Noise  High frequency hearing loss  Speech frequency hearing loss
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号