首页 | 本学科首页   官方微博 | 高级检索  
     

局部振动剂量反应关系及卫生标准的研究
引用本文:周德林 陈力. 局部振动剂量反应关系及卫生标准的研究[J]. 中华预防医学杂志, 1989, 23(1): 23-26
作者姓名:周德林 陈力
摘    要:


关 键 词:局部振动 剂量 卫生 标准 振动病

Research on the dose-response relationship of hand transmitted vibration and its hygienic standard
D L Zhou,L Chen. Research on the dose-response relationship of hand transmitted vibration and its hygienic standard[J]. Chinese Journal of Preventive Medicine, 1989, 23(1): 23-26
Authors:D L Zhou  L Chen
Abstract:
According to ISO 5349-1986, the akw(4) was 9.04-41.47m/s2 which was measured and calculated in 5 types of instruments: chain saw, cleaner, rock driller, riveter & emery wheel. There were 170 cases with white finger through epidemiologic investigation on 5 types of workers in 1,675 persons. Based on the work mentioned above, a formula, which represented worker cumulative exposure to vibration was deduced: D = [(a2kw(4).T)1/2.Y.d]2 Furthermore, the dose-response relationship of hand transmitted vibration and prevalence of white finger was computed, the regression equation was: P = 1.0904X - 6.214 2 Under precondition of exposure to vibration for 20 years with 90% of workers having no white fingers, the limit of hygienic standard of hand transmitted vibration in china should be set at 4 hours and as akw(4) less than or equal to 5 m/s2 based on the regression equation.