空气流量对微孔滤膜空气微生物采样器采样效果的影响 |
| |
引用本文: | 胡庆轩 徐秀芝. 空气流量对微孔滤膜空气微生物采样器采样效果的影响[J]. 中国消毒学杂志, 1997, 14(4): 229-230 |
| |
作者姓名: | 胡庆轩 徐秀芝 |
| |
作者单位: | 军事医学科学院微生物流行病研究所 |
| |
摘 要: | ![]() 经用微孔滤膜(孔径0.45μm)空气微生物采样器对100m3室内空气采样检测,采样时间均为3分钟,空气流量为28.3~100.0L/min,所测空气浮游菌含量随采样空气流量增加而减少。
|
关 键 词: | 空气浮游菌量 空气采样 空气流量 |
INFLUENCE OF VOLUME OF AIR FLOW ON EFFICACY OF AIR MICROORGANISM SAMPLER WITH A MICROPOROUS FILM |
| |
Abstract: | ![]() Examination of air in a room of 100 m3 in size with an air microorganism sampler with a microporous film (the diameter of hole is 0.45 μm) indicated that when the sampling time was 3 min and the air flow was 28.3~100.0 L/min, the number of bacteria sampled from air decreased with increasing air flow. |
| |
Keywords: | number of bacteria suspending in air air sampling air flow |