首页 | 本学科首页   官方微博 | 高级检索  
     

SD附着体固位远中游离端可摘局部义齿三维有限元应力分析
引用本文:肖艳,曾剑玉,张振庭,温颖. SD附着体固位远中游离端可摘局部义齿三维有限元应力分析[J]. 口腔颌面修复学杂志, 2007, 8(1): 1-3,6
作者姓名:肖艳  曾剑玉  张振庭  温颖
作者单位:1. 首都医科大学口腔医学院修复科,北京,100050
2. 首都医科大学口腔医学院,北京,100050
摘    要:
目的:对比分析刚性及弹性附着体义齿的应力分布,为临床选用附着体提供理论参考。方法:建立下颌第二磨牙游离缺失的附着体义齿三维模型。采用有限元应力分析方法,分析2种附着体义齿基牙应力分布情况。结果:(1)在垂直载荷下,2种附着体基牙在牙槽嵴顶处均有应力集中。弹性附着体基牙牙根主应力下降26%-58%;剩余牙槽嵴应力峰值减小50%。(2)斜向载荷时,应力集中更明显,弹性附着体应力峰值仍有一定减小。结论:弹性附着体固位的可摘局部义齿,更有利于保护基牙及支持组织,保护剩余牙槽嵴。

关 键 词:附着体 义齿 局部 可摘 牙周支持组织 应力分析 有限元法
文章编号:1009-3761(2007)01-0001-04
修稿时间:2006-11-05

Three-dimensional finite element analysis of SD attachment retained distal-extension removable partial denture
XIAO Yan,ZENG Jian-yu,ZHANG Zhen-ting,WEN Ying. Three-dimensional finite element analysis of SD attachment retained distal-extension removable partial denture[J]. Chinese Journal of Prosthodontics, 2007, 8(1): 1-3,6
Authors:XIAO Yan  ZENG Jian-yu  ZHANG Zhen-ting  WEN Ying
Affiliation:Faculty of Stomatology, Capital University of Medical Sciences, Belting 100050, China
Abstract:
Objective: To compare and analyze the stress level of rigid and resilient attachment-retained distal extension RPD. Provide a guide in selecting attachment properly in practice. Methods: The three-dimensional finite element method was used to investigate the stress distribution of the abutment and its support tissue with rigid /resilient attachment retained distal-extension removable partial denture under 100N vertical and lingual laod. Two idealized 3-dimensional finite element computer models were built, which consisted of a mandibular posterior segment and a RPD retained by attachment. Results: 1.Under vertical load, the most extreme stress values were located at the alveolar ridge crest distal/mesial to the abutment of two type of attachment. The principal stress of the abutment with resilient attachment was significantly decreased from 26% to 58%and well- distributed, the stress value of residual ridge was reduced by 50%. 2. Under the oblique load, the maximal stress was much higher than that under vertical load. The maximum stresse of resilient attachment was still decreased. Conclusions: Resilient attachment was more favorable than the rigid one to protect the abutment and its support tissue, and to preserve the residual ridge.
Keywords:attachment   denture, partial, removable   periodontal support tissue   stress analysis   finite element method
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号