首页 | 本学科首页   官方微博 | 高级检索  
     


Development of a high-fidelity minimally invasive mitral valve surgery simulator
Authors:Peyman Sardari Nia  Jean H.T. Daemen  Jos G. Maessen
Affiliation:1. Department of Cardiothoracic Surgery, Maastricht University Medical Center, Maastricht, The Netherlands;2. Faculty of Health, Medicine and Life Sciences (FHML), Cardiovascular Research Institute Maastricht (CARIM), Maastricht, The Netherlands
Abstract:

Objectives

The aim of this study was to develop a high-fidelity minimally invasive mitral valve surgery (MIMVS) simulator.

Methods

The process of industrial serial design was applied based on pre-set requirements, acquired by interviewing experienced mitral surgeons. A thoracic torso with endoscopic and robotic access and disposable silicone mitral valve apparatus with a feedback system was developed. The feedback system was based on 4 cameras around the silicone valve and an edge detection algorithm to calculate suture depth and width. Validity of simulator measurements was assessed by comparing simulator-generated values with measurements done manually on 3-dimensional reconstructed micro-computed tomography scan of the same sutures. Independent surgeons tested the simulator between 2014 and 2018, whereupon an evaluation was done through a questionnaire.

Results

The feedback system was able to provide width and depth measurements, which were subsequently scored by comparison to pre-set target values. Depth did not significantly differ between simulator and micro-computed tomography scan measurements (P = .139). Width differed significantly (P = .001), whereupon a significant regression equation was found (P < .0001) to calibrate the simulator. After calibration, no significant difference was found (P = .865). In total, 99 surgeons tested the simulator and more than agreed with the statements that the simulator is a good method for training MIMVS, and that the mitral valve and suture placement looked and felt realistic.

Conclusions

We successfully developed a high-fidelity MIMVS simulator for endoscopic and robotic approaches. The simulator provides a platform to train skills in an objective and reproducible manner. Future studies are needed to provide evidence for its application in training surgeons.
Keywords:minimally invasive mitral valve surgery  high-fidelity  simulator  endoscopic  robotic  3D  3-dimensional  CT  computed tomography  MIMVS  minimally invasive mitral valve surgery
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏