首页 | 本学科首页   官方微博 | 高级检索  
     


Assaying the circulating factor VIII activity in hemophilia A patients treated with recombinant factor VIII products
Authors:Mikaelsson Marianne  Oswaldsson Ulla
Affiliation:Kabio HB, Stockholm, Sweden. ulla.oswaldsson@biovitrum.com
Abstract:Large discrepancies between factor VIII assay methods have been reported from pharmacokinetic studies of recombinant factor VIII concentrates. In the assay of postinfusion patient plasma samples, traditional activated partial thromboplastin time (aPTT)-based one-stage clotting methods usually give results that are 20 to 50% lower than those obtained by chromogenic substrate assays. Investigations into the cause of these discrepancies have shown that the choice of phospholipid in the one-stage assay is crucial. The use of platelets or liposomes resembling platelet factor 3 instead of traditional aPTT reagents results in an increase in the apparent one-stage activity and a fairly good correlation with the chromogenic results. These and other functional test results, antigen measurements as well as clinical data, support the view that the chromogenic assay most accurately reflects the therapeutic effect. In addition to the differences among assay methods, there is also a discrepancy between the World Health Organization (WHO) standards for concentrates and plasma. The use of product-specific standards, prepared by diluting the factor VIII concentrate into hemophilic plasma, when assaying postinfusion plasma samples seems to be a feasible approach to overcome the problems encountered in pharmacokinetic studies.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号