Prosthesis displacement as a complication of reduction of a dislocated total hip arthroplasty |
| |
Authors: | Mark D. Holt MA FRCS |
| |
Affiliation: | aDepartment of Trauma and Orthopaedic Surgery, University of Wales College of Medicine, Cardiff, United Kingdom |
| |
Abstract: | Acute displacement at the cement—prosthesis interface of the femoral component of a hip arthroplasty that occurred as a consequence of attempted reduction of a dislocation is described. Although this complication is theoretically possible with a polished tapered stem design, it is previously unrecognized, and may be avoidable if fluoroscopic control is used during closed reduction of a dislocation. |
| |
Keywords: | arthroplasty (cemented) dislocation complication manipulation |
本文献已被 ScienceDirect 等数据库收录! |