首页 | 本学科首页   官方微博 | 高级检索  
     


The ONG capsular lens,report of 100 implantations
Authors:T. S. Ong
Affiliation:(1) Schieland Hospital, Schiedam, The Netherlands
Abstract:This Capsular Lens (ONG, type IV, to be called lsquoO.C.L.rsquo) has been developed for routinely performed extracapsular cataract extraction with lens implantation. The fundamental surgical procedure was based on continuing experience with the bimanual aspiration-irrigation technique and system developed by the author in 1971. The biomechanical properties of the asymmetric partly flexible, haptic loops are designed to give tensionfree fixation in two capsular pockets. The plano-anterior position of the lens ensures well-defined irido-lenticular clearance and proper alignment of the convex side with the posterior capsule. Consequently no iridectomy or iridotomy is needed for proper aqueous flow.
Keywords:bimanual irrigation-aspiration  BIMA-Unit  shock-suction technique  capsulopuncture convex-concave figure  capsulotomy lateral  double capsular-pocket fixation  irido-lenticular clearance    /content/h98v3745401u03r1/xxlarge8216.gif"   alt="  lsquo"   align="  BASELINE"   BORDER="  0"  >O.C.L.  /content/h98v3745401u03r1/xxlarge8217.gif"   alt="  rsquo"   align="  BASELINE"   BORDER="  0"  >  asymmetric loops  plano-anterior position  tensionless fixation