首页 | 本学科首页   官方微博 | 高级检索  
     

戊二醛浸泡口腔医疗器械对HBsAg破坏效果的检测
引用本文:杨聚才,安银东,黄萍,王虹. 戊二醛浸泡口腔医疗器械对HBsAg破坏效果的检测[J]. 中国消毒学杂志, 1998, 15(4): 235-236
作者姓名:杨聚才  安银东  黄萍  王虹
作者单位:第四军医大学口腔医学院西安 710032
摘    要:
试验表明,对口腔医疗器械,用05%戊二醛溶液浸泡8h,或10%戊二醛溶液浸泡7min,均不能使其上的HBsAg抗原性全部阴转,至少需用20%戊二醛溶液浸泡7min才可达到上述要求

关 键 词:口腔医疗器械消毒  戊二醛  HBsAg
修稿时间:1997-11-28

EXAMINATION OF EFFICACY OF GLUTARALDEHYDE IMMERSION OF STOMATOLOGIC INSTRUMENTS IN DESTROYING HBsAg
Yang Jucai,et al School of Stomatology,Fourth Military Medical University,Xi'an. EXAMINATION OF EFFICACY OF GLUTARALDEHYDE IMMERSION OF STOMATOLOGIC INSTRUMENTS IN DESTROYING HBsAg[J]. Chinese Journal of Disinfection, 1998, 15(4): 235-236
Authors:Yang Jucai  et al School of Stomatology  Fourth Military Medical University  Xi'an
Affiliation:Yang Jucai,et al School of Stomatology,Fourth Military Medical University,Xi'an 710032
Abstract:
Immersion of stomatologic instruments in 0 5% glutaraldehyde solution for 8 h or in 1 0% glutaraldehyde solution for 7 min could not cause full negative conversion of antigenicity of HBsAg on these instruments In order to attain full negative conversion, at least immersion in 2 0% glutaraldehyde solution for 7 min is required
Keywords:disinfection of stomatologic instruments glutaraldehyde HBsAg  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号