Enucleation combined with orbital implants for malignant melanoma of the uvea |
| |
Authors: | J. Saßmannshausen N. Bornfeld A. Kluge W. Sauerwein F. Härting A. Wessing |
| |
Affiliation: | (1) Department of Ophthalmology, Essen University (GHS), Hufelandstr 55, D 4300 Essen 1, FRG;(2) Department of Radiology, Essen University (GHS), FRG |
| |
Abstract: | Advanced malignant melanomas of the uvea unsuited for an eye salvaging approach require enucleation of the tumor containing eye. A series of 68 patients is reported who underwent enucleation combined with insertion of a spherical dura-encased implant after 30 Gray pre-irridiation therapy of the orbit. Postoperative results with special attention to cosmetic outcome and motility of the prosthesis suggest that the insertion of an orbital implant should be preferred to the enucleation with no implant. |
| |
Keywords: | malignant melanoma of the uvea enucleation post enucleation socket syndrome orbital implant |