首页 | 本学科首页   官方微博 | 高级检索  
检索        


Enucleation combined with orbital implants for malignant melanoma of the uvea
Authors:J Saßmannshausen  N Bornfeld  A Kluge  W Sauerwein  F Härting  A Wessing
Institution:(1) Department of Ophthalmology, Essen University (GHS), Hufelandstr 55, D 4300 Essen 1, FRG;(2) Department of Radiology, Essen University (GHS), FRG
Abstract:Advanced malignant melanomas of the uvea unsuited for an eye salvaging approach require enucleation of the tumor containing eye. A series of 68 patients is reported who underwent enucleation combined with insertion of a spherical dura-encased implant after 30 Gray pre-irridiation therapy of the orbit. Postoperative results with special attention to cosmetic outcome and motility of the prosthesis suggest that the insertion of an orbital implant should be preferred to the enucleation with no implant.
Keywords:malignant melanoma of the uvea  enucleation  post enucleation socket syndrome  orbital implant
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号