首页 | 本学科首页   官方微博 | 高级检索  
     


Mayak film dosimeter response studies, part iii: application to worker dose assessment
Authors:Smetanin M  Vasilenko E K  Scherpelz R I
Affiliation:Mayak Production Association, Ozyorsk, Russia.
Abstract:
This paper describes the methods used to correct individual dosimeter readings for workers to obtain estimates of worker doses received at the Mayak Production Association (Mayak PA). Film dosimeters were used at Mayak PA for worker monitoring from 1948 until 1992. The method requires a determination of the relationship between the absorbed dose in film emulsion and the dose in air under calibration conditions, which is then extended to exposures in the actual radiation fields of the workplace. Corrections needed to account for actual workplace exposure conditions were determined by modeling with the Monte Carlo radiation transport computer code MCNP. Correction factors were developed to convert from dosimeter reading to a realistic worker dose. The method was applied as a basis for individual dose reconstruction using film dosimeters in realistic photon spectra and geometries at Mayak PA work areas.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号