首页 | 本学科首页   官方微博 | 高级检索  
检索        

配戴角膜塑形镜和框架眼镜对近视儿童周边屈光度影响的随机对照临床试验
引用本文:魏士飞,李仕明,孙芸芸,康梦田,孟博,冉安然,严然,白雅雯,Zhuo Chen,王宁利.配戴角膜塑形镜和框架眼镜对近视儿童周边屈光度影响的随机对照临床试验[J].中华实验眼科杂志,2017(10):930-935.
作者姓名:魏士飞  李仕明  孙芸芸  康梦田  孟博  冉安然  严然  白雅雯  Zhuo Chen  王宁利
作者单位:1. 首都医科大学附属北京同仁医院 北京同仁眼科中心 北京市眼科学与视觉科学重点实验室,北京,100730;2. Lakewood Eye Care,Houston, TX 77070, USA
基金项目:国家973重点基础研究发展计划项目(2011CB504601),国家自然科学基金重大国际合作项目(81120108007),国家自然科学基金项目(81300797)National 973 Key Basic Research and Development Project(2011CB504601),Major International Cooperation Projects of the National Natural Science Foundation(81120108007),National Natural Science Foundation of China(81300797)
摘    要:背景 临床实践发现角膜塑形镜具有延缓近视及眼轴长度进展的效果,但对于角膜塑形镜配戴的相关作用机制,特别是角膜塑型术对视网膜中心和周边的离焦作用机制尚不完全清楚. 目的 观察低中度近视儿童配戴角膜塑形镜和框架眼镜6个月后周边屈光度以及相对周边屈光度(RPR)的变化.方法 采用随机对照临床试验方法,于2014年6月至2015年1月在北京同仁眼科中心招募屈光度为-0.50~-6.00 D的低中度近视儿童100例,平均年龄(11.0±1.9)岁,均纳入右眼进行研究.受试者按入组顺序编号后由SAS统计软件PROC PLAN过程语句随机均分为角膜塑形镜组和框架眼镜组,每组50例50眼,戴镜时间均为6个月.采用开放视野红外自动验光仪分别测量戴镜前后中央0°、颞侧15°和30°、鼻侧15°和30°径线的屈光度,观察并比较各组受试眼戴镜前后周边屈光度和RPR(周边屈光度与中央屈光度差值)变化趋势. 结果 角膜塑形镜组和框架眼镜组受试者戴镜前屈光度分别为(-3.35±1.31)D和(-3.01±1.15)D,差异无统计学意义(P=0.201).角膜塑形镜组受试眼戴镜前鼻侧30°、鼻侧15°、中央0°、颞侧15°和颞侧30°径线周边屈光度分别为(-2.28±1.60)、(-3.28±1.41)、(-3.40±1.23)、(-3.38±1.12)和(-2.09±1.29)D,受试眼除颞侧30°外戴镜后6个月近视度数均下降,戴镜前后鼻侧30°、鼻侧15°、中央0°、颞侧15°屈光度变化值分别为(0.29±1.67)、(0.85±1.66)、(0.92±1.76)和(0.66±1.66)D,其中鼻侧15°、中央0°、颞侧15°与戴镜前相比差异均有统计学意义(均P<0.05).框架眼镜组受试者戴镜前鼻侧30°、鼻侧15°、颞侧15°和颞侧30°径线周边屈光度分别为(-1.88±1.30)、(-2.66±1.18)、(-2.89±1.27)和(-1.94±1.31)D,戴镜后6个月上述各径线近视度数均增加,戴镜前后变化值分别为(-0.25±0.80)、(-0.43±0.67)、(-0.32±0.64)和(-0.22±0.75)D,与戴镜前比较差异均有统计学意义(均P<0.05).角膜塑形镜组受试者戴镜前各径线RPR均为远视性离焦状态,戴镜后6个月颞侧15°和颞侧30°RPR变为近视性离焦状态.框架眼镜组受试者戴镜前各径线RPR均为远视性离焦状态,戴镜后各径线RPR均呈远视性离焦加深状态.结论 长期配戴角膜塑形镜能够使近视儿童的周边屈光度发生远视性漂移,视网膜周边呈现相对近视性离焦,而长期配戴框架眼镜则使周边屈光度发生近视漂移,视网膜周边远视性离焦加深.角膜塑形镜配戴可能通过改变周边屈光度而达到减缓近视进展的目的.

关 键 词:近视/防控  儿童  接触镜  随机对照临床试验  周边屈光度  角膜塑形镜  框架眼镜

A randomized controlled clinical trial on the effects of wearing orthokeratology and spectacles on ocular peripheral refraction in myopic children
Authors:Wei Shifei  Li Shiming  Sun Yunyun  Kang Mengtian  Meng Bo  Ran Anran  Yan Ran  Bai Yawen  Zhuo Chen  Wang Ningli
Abstract:Background It has been reported that orthokeratology has the effects of slowing down myopia progression and axial elongation.However,the affecting mechanism of orthokeratology wearing on ocular peripheral refraction is still not elucidated.Objective This study was to observe and compare the changes of ocular peripheral refraction and relative peripheral refraction (RPR) in low to moderate myopic eyes of children after wearing orthokeratology lens and spectacles for 6 months.Methods A randomized controlled clinical trial was carried out after approval of Ethic Committee of Beijing Tongren Hospital and informed consent of guardians of the children.One hundred myopic children aged (ll.0±1.9) years were recruited in Beijing Tongren Hospital from June 2014 to January 2015,with the diopter of-0.50 to-6.00 D.The subjects were randomized into orthokeratology group and spectacles group by the process PLAN PROC of software SAS 9.1.3,50 for each group.The subjects in the orthokeratology group wore orthokeratology lens for 6 months and those in the spectacles group wore spectacles for the same period.An infrared open-field autorefractor was employed to measure the refraction at central 0°,temporal 15°,temporal 30°,nasal 15°and nasal 30° radial lines before and after wearing lens for the assessment and comparison of the changes of peripheral refraction and RPR.Results There was no significant difference in spherical equivalent between the orthokeratology group and the spectacles group before wearing lens (-3.35±1.31] D versus -3.01± 1.15] D,P =0.20).The peripheral refraction values in the orthokeratology group were (-2.28 ± 1.60),(-3.28±1.41),(-3.40±1.23),(-3.38±1.12) and (-2.09±1.29)D at nasal 15°and nasal30°,central,temporal 15° and temporal 30°radial lines before wearing lens,and reduced by (0.29±1.67),(0.85±1.66),(0.92±1.76) and (0.66±1.66) D at nasal 30°,nasal 15°,central and temporal 15° after wearing lens,respectively,with significant differences at nasal 15°,central and temporal 15°(all at P<0.05).The peripheral refraction values in the spectacles group were (-1.88±1.30),(-2.66±1.18),(-2.89±1.27) and (-1.94±1.31)D at nasal 15°,nasal 30°,temporal 15 ° and temporal 30°,radial lines before wearing lens and increased by (-0.25±0.80),(-0.43 ±0.67),(-0.32±0.64) and (-0.22±0.75)D after wearing lens,respectively,with significant differences between before and after wearing lens (all at P<0.05).The RPR shifted from hyperopia defocus to myopia defocus before and after wearing lens in temporal 15° and 30° radial lines in the orthokeratology group,and at various radial lines in the spectacles group,the RPR showed gradually worsening of hyperopia defocus.Conclusions Long-term wearing of orthokeratology results in a hyperopia shifting in myopic children by exposing the peripheral retina towards relative myopia defocus,whereas wearing spectacles leads to a relative hyperopia defocus on retina.Thus,orthokeratology may slow down the myopia progression.
Keywords:Myopia/prevention & control  Children  Contact lenses  Randomized controlled clinical trail  Peripheral refraction  Orthokeratology  Spectacles
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号