首页 | 本学科首页   官方微博 | 高级检索  
     


Bone structure changes in hip joint endoprosthesis implantation over the course of many years. A quantitative study
Authors:M Hahn  M Vogel  F Eckstein  M Pompesius-Kempa  G Delling
Affiliation:Abteilung Osteopathologie, Universit?t Hamburg.
Abstract:The stability of implanted artificial joints is limited. One main factor for this is the change of the bone tissue near the implant. Therefore we studied femura with stem endoprostheses derived from autopsy. All specimens were cut in horizontal and longitudinal sections. X-rays were made of all sections. Then the specimens were embedded undecalcified and ground to 10 microns. The wellknown phenomenons at the bone cement border were found too. Direct bone cement contact is about 5%. The 4 studied femura show a higher porosity of cortical bone as controls. The loss of cortical bone is up to 40% after 55 months. There is a correlation between new load situation and the localisation of bone loss.
Keywords:
正在获取相似文献,请稍候...
设为首页 | 免责声明 | 关于勤云 | 加入收藏