首页 | 本学科首页   官方微博 | 高级检索  
     

石墨炉原子吸收分光光度法测定冰片中微量铅镉铜
引用本文:江必富,李同莲. 石墨炉原子吸收分光光度法测定冰片中微量铅镉铜[J]. 现代医药卫生, 2011, 27(21): 3215-3217
作者姓名:江必富  李同莲
作者单位:泸州医学院附属中医院,四川泸州,646000
摘    要:
目的:建立石墨炉原子吸收分光光度法测定冰片中微量铅、镉、铜的分析方法.方法:检查波长铅为283.3 nm,镉为228.8nm,铜为324.7 nm;灯电流为10.0 mA;狭缝宽度为0.4 nm.结果:铅在0.0~40.0 ng/mL、镉在0.0~1.0 ng/mL、铜在0~10 ng/mL范围内有较好的线性关系,平均加样回收率分别为98.3%,98.0%,97.3%.结论:石墨炉原子吸收分光光度法测定冰片中微量铅、镉、铜,方法准确、简单、灵敏,被测溶液稳定性好.

关 键 词:石墨炉原子吸收分光光度法  测定  冰片      

Content determination of lead,cadmium and cupper in synthetic borneol by GFAAS
JIA NG Bi-fu , LI Tong-lian. Content determination of lead,cadmium and cupper in synthetic borneol by GFAAS[J]. JOURNAL OF MODERN MEDICINE & HEALTH, 2011, 27(21): 3215-3217
Authors:JIA NG Bi-fu    LI Tong-lian
Affiliation:JIANG Bi-fu,LI Tong-lian(Affiliated Hospital of TCM,Luzhou Medical College,Luzhou,Sichuan 646000,China)
Abstract:
Objective:To establish the graphite furnace atomic absorption spectrometry(GFAAS) method for the determination of trace lead,cadmium and cupper in synthetic borneol.Methods:The detection wavelength was at 283.3 nm for lead,228.8 nm for cadmium and 324.7 nm for cupper,the lamp current was 2.0~3mA and the slit-width was 0.4 nm.Results:In the range of 0.0~40.0 ng/mL for lead,0.0~40.0 ng/mL for cadmium and 0~10 ng/mL for copper,the good linear relationship was revealed.The average recovery rates were 98.3%,98.0% and 97.3% respectively.Conclusion:This method is accurate and reproducible for determining the content of lead,cadmium and cupper in synthetic borneol.
Keywords:Graphite furnace atomic absorption spectrometry(GFAAS)  Determination  Synthetic borneol  Lead  Cadmium  Cupper  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号