摘    要:目的:探讨肝脏成像中磁共振BLADE技术的临床应用价值。方法:2012年5月-2013年5月期间共90例志愿者,采用数字抽取法随机分为三组,扫描序列分别是:A组:T2WI+FS+Trigger,K空间填充100%;B组:T2WI+FS+Trigger+BLADE,K空间填充100%;C组:T2WI+FS+Trigger+BLADE,K空间填充200%。对不同序列图像伪影评分及正常肝脏实质信噪比(SNR)进行统计学分析。结果:正常肝脏三组伪影评分有明显统计学差异(F=11.037,P〈0.001),A组伪影统计学上多于B组及C组(P值分别为0.003及0.0012);正常肝脏三组SNR有明显统计学差异(F=11.037,P〈0.001),A组统计学上明显低于B组及C组(P值分别为0.031及0.023)。结论:BLADE技术的应用,可减少肝脏MRI影像伪影,提高影像质量。

关 键 词:  磁共振成像
收稿时间:2013-12-16

Clinical application of magnetic resonance BLADE technology in liver imaging
LIU Hao,YAO Xiu-zhong,CHEN Cai-zhong,ZHANG Shu-jie,HE Ying,ZENG Meng-su.Clinical application of magnetic resonance BLADE technology in liver imaging[J].Journal of China Clinic Medical Imaging,2014,25(6):406-408.
Authors:LIU Hao  YAO Xiu-zhong  CHEN Cai-zhong  ZHANG Shu-jie  HE Ying  ZENG Meng-su
Institution:1. Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China;2. Department of Radiology, Longhua Hospital, Shanghai Traditional Chinese Medicine University, Shanghai 200032, China)
Abstract:Objective: To investigate the clinical value of BLADE sequence in MRI of liver. Methods: Ninty volunteers were enrolled during the period of May 2012 to May 2013. All subjects were randomly divided into three groups with digital extraction method: Group A, T2WI+FS+Trigger and K space with 100% filling. Group B: T2WI+FS+Trigger+BLADE and K space with 100% filling. Group C: T2WI+FS+Trigger+BLADE and K space with 200% filling. Image artifacts and signal to noise ratio (SNR) of normal liver parenchyma were statistically analyzed among different sequences. Results: Imaging artifacts scores of normal liver reached statistically significant difference among three groups (F=11.037, P〈0.001). Imaging artifacts scores of normal liver in A group was statistiCally higher than group B and group C (P=0.003 and P=0.001 2 respectively); SNR of normal liver reached statistically significant difference among three groups(F=11.037, P〈0.001). SNR of normal liver in A group was statistically lower than group B and group C(P=0.031 and P=0.023 respectively). Conclusion: BLADE technology can reduce artifacts in MR1 of liver and improve its image quality.
Keywords:Liver  Magnetic resonance imaging