Determination of procaine in equine plasma and urine by high-performance liquid chromatography. |
| |
Authors: | A J Stevenson M P Weber F Todi M Mendonca J D Fenwick L Young E Kwong F Chen P Beaumier S Timmings |
| |
Affiliation: | Race Track Division, Agriculture Canada, Ottawa and Jerseyville, Ontario. |
| |
Abstract: | The variability in plasma and urine equine procaine measurement between three independent laboratories using current methods led to the development of a sensitive, reliable, and reproducible high-performance liquid chromatographic method. Standardbred mares were administered either a penicillin G procaine preparation intramuscularly or procaine hydrochloride subcutaneously, and blood and urine were collected at defined time intervals. By HPLC the detection limits for procaine in plasma and urine were 1 and 10 ng/mL, respectively. In contrast procaine in plasma could not be detected by GC-NPD, while the urinary detection limit was 50 ng/mL. The concentration of fluoride in the collection tubes and repetitive freeze-thawing modified plasma procaine measurement. Urinary pH was a factor in estimation of urine procaine levels with greater recovery and reproducibility of results at pH 5 as compared to pH 7. This HPLC method provides a simple, sensitive, and reliable quantitation of procaine in equine plasma and urine. |
| |
Keywords: | |
|
|