首页 | 本学科首页   官方微博 | 高级检索  
     

尿中四氢呋喃的顶空固相微萃取-气相色谱测定法
引用本文:Han ZH,Fu S,Yu KP. 尿中四氢呋喃的顶空固相微萃取-气相色谱测定法[J]. 中华劳动卫生职业病杂志, 2011, 29(2): 150-151. DOI: 10.3760/cma.j.issn.1001-9391.2011.02.022
作者姓名:Han ZH  Fu S  Yu KP
作者单位:湖南省劳动卫生职业病防治所中心实验室,长沙,410007
摘    要:目的 建立测定尿中四氢呋喃的顶空固相微萃取-气相色谱法.方法 以顶空固相微萃取技术处理尿样,用带氢焰离子化检测器的气相色谱仪测定尿中的四氢呋喃.通过对萃取头类型、萃取时间和温度、解吸温度和时间等影响萃取效率的因素的研究,获得了优化的试验条件.结果 在优化条件下,方法 的线性较好,样品的加标回收率为93.0%~100.8%,相对标准偏差为0.96%~3.85%,检出限可以达到0.5μg/L.结论 该方法 适用于尿中四氢呋喃的测定.
Abstract:
Objective Headspace solid-phase microextraction (HS-SPME) was used pre-concentration procedure for the determination of tetrahydrofuran in urine by gas chromatography with hydrogen flame detector. Methods Several parameters controlling SPME was studied and optimised: SPME fiber, extraction time and extraction temperature, desorption time and desorption temperature. Results Under optimal conditions, the correlation coefficient was 0.9998 and good recoveries (range from 93.0%~100.8%) were achieved,the detection limit was 0.5μg/L. Conclusion The method can be applied to the determination of trace amount of tetrahydrofuran in urine.

关 键 词:顶空固相微萃取  色谱法,气相  四氢呋喃,尿

Determination of tetrahydrofuran in urine by headspace solid-phase microextraction and gas chromatography
Han Zhi-hui,Fu Sheng,Yu Ke-ping. Determination of tetrahydrofuran in urine by headspace solid-phase microextraction and gas chromatography[J]. Chinese journal of industrial hygiene and occupational diseases, 2011, 29(2): 150-151. DOI: 10.3760/cma.j.issn.1001-9391.2011.02.022
Authors:Han Zhi-hui  Fu Sheng  Yu Ke-ping
Affiliation:Institute of Labour Hygiene and Occupational Diseases of Hunan Province, Changsha, Hunan Province 410007, China.
Abstract:Objective Headspace solid-phase microextraction (HS-SPME) was used pre-concentration procedure for the determination of tetrahydrofuran in urine by gas chromatography with hydrogen flame detector. Methods Several parameters controlling SPME was studied and optimised: SPME fiber, extraction time and extraction temperature, desorption time and desorption temperature. Results Under optimal conditions, the correlation coefficient was 0.9998 and good recoveries (range from 93.0%~100.8%) were achieved,the detection limit was 0.5μg/L. Conclusion The method can be applied to the determination of trace amount of tetrahydrofuran in urine.
Keywords:Headspace solid-phase microextraction  Gas chromatography  Urine  Tetrahydrofuran
本文献已被 万方数据 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏