首页 | 本学科首页   官方微博 | 高级检索  
     

成人距骨数字化计算机三维模型解剖学测量及对个性化治疗的意义
引用本文:张艳东,刘奕蓉,赵国志,李志军. 成人距骨数字化计算机三维模型解剖学测量及对个性化治疗的意义[J]. 中国临床康复, 2012, 0(35): 6466-6470
作者姓名:张艳东  刘奕蓉  赵国志  李志军
作者单位:[1]河北联合大学,河北省唐山市063000 [2]河北联合大学基础医学院解剖教研室,河北省唐山市063000 [3]河北省唐山市第二医院,河北省唐山市063000 [4]内蒙古医学院基础医学院,内蒙古自治区呼和浩特市010059
摘    要:
背景:距骨作为踝关节重要组成部分之一,其形态直接影响着踝关节的稳定性和发病率。目的:建立距骨数字化计算机三维模型,测量相关解剖数据,为踝部的手术设计提供解剖学参数。方法:正常成人志愿者60例,男30例,女30例,进行CT扫描,扫描层厚1.25mm,扫描间距1.25mm,重建层厚0.625mm,重建间距0.625mm,Fov30×30mm,矩阵512×512dpi,球管电压150kV,电流260mA,将扫描原始数据以DICOM格式导入PC计算机,利用三维重建软件(比利时产MaterrialiseMimics13.01测试版)行后处理并测量。并按性别分组进行统计分析。结果与结论:重建的距骨数字化虚拟可视模型能够从多平面进行观察及测量,距骨长、距骨宽、距骨高,滑车前宽、滑车后宽、滑车高、滑车长,内踝面长,外踝面长的测量值男性大于女性。测量获取的距骨解剖学数据对距骨疾患、手术器械的设计、个性化治疗方案的制定等均有重要参考意义。

关 键 词:距骨  三维重建  解剖学测量  数字化图像  个性化治疗

Anatomical measurement of three-dimensional reconstruction of adult talus and its significance for individualized treatment
Zhang Yan-dong,Liu Yi-rong,Zhao Guo-zhi,Li Zhi-jun. Anatomical measurement of three-dimensional reconstruction of adult talus and its significance for individualized treatment[J]. Chinese Journal of Clinical Rehabilitation, 2012, 0(35): 6466-6470
Authors:Zhang Yan-dong  Liu Yi-rong  Zhao Guo-zhi  Li Zhi-jun
Affiliation:1Hebei Union University, Tangshan 063000, Hebei Province, China; 2Department of Anatomy, School of Medicine, Hebei Union University, Tangshan 063000, Hebei Province, China; 3Second Hospital of Tangshan City, Tangshan 063000, Hebei Province, China; 4School of Medicine, Inner Mongolia Medical College, Hohhot 010059, Inner Mongolia Autonomous Region, China
Abstract:
BACKGROUND: Talus serves as an important part of the ankle joint, and its form directly affects the stability and morbidity of the ankle joint. OBJECTIVE: To establish digital three-dimensional computer model of the talus, and then to measure the relevant anatomical data to provide anatomical parameters for operative design of the ankle joint. METHODS: Sixty normal adult volunteers containing 30 males and 30 females were treated with CT scan. Scan slice thickness was 1.25 mm, scanning pitch was 1.25 mm, reconstruction slice thickness was 0.625 mm, reconstruction spacing was 0.625 mm, Fov 30×30 mm, matrix was 512×512 dpi, tube voltage was 150 kV and current was 260 mA. The original scan data were introduced into PC computer with the form of DICOM. Three-dimensional reconstruction software (Materrialise Mimics 13.01 test version produced in Belgium) was used for post-processing and measurement. Statistical analysis was preformed according to gender. RESULTS AND CONCLUSION: The digital and virtual reconstruction model of talus could be observed and measured from multi-plane. Measurements of the length of the talus, width of the talus, height of the talus, the anterior width of the trochlea of talus, the posterior width of the trochlea of talus, the height of trochlea of talus, the length of trochlea of talus, the length of medial malleolar facet and the length of lateral malleolar facet in the male were larger than those in the female. Anatomical data from measurement have an important impact on talus diseases, the design of surgical instruments and the formulation of individualized treatment programs.
Keywords:
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号