German Multicenter Experience With a New Leaflet-Based Transcatheter Mitral Valve Repair System for Mitral Regurgitation |
| |
Affiliation: | 1. Department of Cardiology, Heart Centre, Faculty of Medicine, University of Cologne, Cologne, Germany;2. Department of Cardiology, Heart Center Leipzig at University of Leipzig, Leipzig, Germany;3. Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, Medical Faculty, Essen, Germany;4. Medizinische Klinik I, Department of Cardiology, University of Giessen, Giessen, Germany;5. Heart Valve Center Mainz, Center of Cardiology, Cardiology I, University Medical Center Mainz, Mainz, Germany;6. General and Interventional Cardiology, Heart and Diabetes Centre NRW, Bad Oeynhausen, Germany;7. Ruhr University Bochum, Bochum, Germany;8. Division of Cardiology, Pulmonology, and Vascular Medicine, Medical Faculty, University of Düsseldorf, Düsseldorf, Germany;9. Medical Clinic I, Department of Cardiology, St-Johannes-Hospital, Dortmund, Germany;10. Medizinische Klinik und Poliklinik I der Ludwig-Maximilians-Universität München, Munich, Germany;11. Heart Center Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany |
| |
Abstract: | ObjectivesThe aim of this study was to investigate the procedural and short-term safety and efficacy of a new leaflet-based transcatheter mitral valve repair system.BackgroundThe PASCAL repair system has been recently approved for percutaneous treatment of mitral regurgitation (MR). Novel characteristics are broad paddles positioned around a central spacer and the ability for independent leaflet capture.MethodsProcedural and 30-day outcomes were investigated in the first 309 patients with symptomatic MR 3+/4+ treated with the PASCAL repair system at 10 sites. Primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE).ResultsAmong the 309 patients (mean age 77 ± 10 years, 42% women, mean European System for Cardiac Operative Risk Evaluation II score 5.8 ± 4.5%) included in this study, MR etiology was degenerative in 33%, functional in 52%, and mixed in 16%. Eighty-six percent of patients were in New York Heart Association functional class III or IV. The technical success rate was 96%. Of 308 patients discharged alive, MR was ≤2+ in 93.5%. At 30 days, the MAE rate was 4.1%, with an estimated all-cause mortality rate of 2.0%, and 72% of patients were in New York Heart Association functional class ≤II (p < 0.001). Rates of device success and CLASP (Edwards PASCAL Transcatheter Mitral Valve Repair System Study) trial–defined clinical success were 81.9% and 86.9%, respectively. Single-leaflet device attachment occurred in 7 patients (2.3%).ConclusionsMitral valve repair with the PASCAL system in the early post-approval phase was effective and safe, with high procedural success rates and low rates of MAE. MR was significantly reduced, accompanied by significant improvement in functional status. |
| |
Keywords: | mitral regurgitation PASCAL transcatheter mitral valve repair IQR" },{" #name" :" keyword" ," $" :{" id" :" kwrd0030" }," $$" :[{" #name" :" text" ," _" :" interquartile range MAE" },{" #name" :" keyword" ," $" :{" id" :" kwrd0040" }," $$" :[{" #name" :" text" ," _" :" major adverse event(s) MR" },{" #name" :" keyword" ," $" :{" id" :" kwrd0050" }," $$" :[{" #name" :" text" ," _" :" mitral regurgitation MVARC" },{" #name" :" keyword" ," $" :{" id" :" kwrd0060" }," $$" :[{" #name" :" text" ," _" :" Mitral Valve Academic Research Consortium NYHA" },{" #name" :" keyword" ," $" :{" id" :" kwrd0070" }," $$" :[{" #name" :" text" ," _" :" New York Heart Association SLDA" },{" #name" :" keyword" ," $" :{" id" :" kwrd0080" }," $$" :[{" #name" :" text" ," _" :" single-leaflet device attachment |
本文献已被 ScienceDirect 等数据库收录! |
|