Temporomandibular joint: improved MR image quality with decreased section thickness. |
| |
Authors: | P L Westesson E Kwok J B Barsotti M Hatala D Paesani |
| |
Affiliation: | Department of Radiology, University of Rochester School of Medicine and Dentistry, NY 14642-8694. |
| |
Abstract: | To determine if the quality of spin-echo magnetic resonance (MR) images of the temporomandibular joint (TMJ) could be improved by reducing section thickness, coronal and sagittal 3.0- and 1.5-mm MR images of the same joints were evaluated. Depiction of the disk, trabecular pattern, and cortex of the condyle was better on coronal 1.5-mm images than on 3.0-mm images (P less than .01), and 1.5-mm sagittal images were better for depiction of the trabecular pattern of the condyle than were 3.0-mm images (P less than .05). The ability of MR imaging with thinner sections to reveal more anatomic details should result in improved diagnostic accuracy. |
| |
Keywords: | |
|
| 点击此处可从《Radiology》浏览原始摘要信息 |
|
点击此处可从《Radiology》下载全文 |
|