首页 | 本学科首页   官方微博 | 高级检索  
     


Detailed 3D models of the induced electric field of transcranial magnetic stimulation coils
Authors:Salinas F S  Lancaster J L  Fox P T
Affiliation:Research Imaging Center, University of Texas Health Science Center at San Antonio, San Antonio, TX 78229, USA.
Abstract:
Previous models neglected contributions from current elements spanning the full geometric extent of wires in transcranial magnetic stimulation (TMS) coils. A detailed account of TMS coil wiring geometry is shown to provide significant improvements in the accuracy of electric field (E-field) models. Modeling E-field dependence based on the TMS coil's wire width, height, shape and number of turns clearly improved the fit of calculated-to-measured E-fields near the coil body. Detailed E-field models were accurate up to the surface of the coil body (within 0.5% of measured) where simple models were often inadequate (up to 32% different from measured).
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏