首页 | 本学科首页   官方微博 | 高级检索  
     


Machine Learning Model for Classifying the Results of Fetal Cardiotocography Conducted in High-Risk Pregnancies
Authors:Tae Jun Park  Hye Jin Chang  Byung Jin Choi  Jung Ah Jung  Seongwoo Kang  Seokyoung Yoon  Miran Kim  Dukyong Yoon
Affiliation:1.Department of Biomedical Informatics, Ajou University School of Medicine, Suwon, Korea.;2.Department of Obstetrics and Gynecology, Ajou University School of Medicine, Suwon, Korea.;3.COSMOSWHALE Inc., Ansan, Korea.;4.Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, Korea.;5.Center for Digital Health, Yongin Severance Hospital, Yonsei University Health System, Yongin, Korea.;6.BUD.on Inc., Jeonju, Korea.
Abstract:PurposeFetal well-being is usually assessed via fetal heart rate (FHR) monitoring during the antepartum period. However, the interpretation of FHR is a complex and subjective process with low reliability. This study developed a machine learning model that can classify fetal cardiotocography results as normal or abnormal.Materials and MethodsIn total, 17492 fetal cardiotocography results were obtained from Ajou University Hospital and 100 fetal cardiotocography results from Czech Technical University and University Hospital in Brno. Board-certified physicians then reviewed the fetal cardiotocography results and labeled 1456 of them as gold-standard; these results were used to train and validate the model. The remaining results were used to validate the clinical effectiveness of the model with the actual outcome.ResultsIn a test dataset, our model achieved an area under the receiver operating characteristic curve (AUROC) of 0.89 and area under the precision-recall curve (AUPRC) of 0.73 in an internal validation dataset. An average AUROC of 0.73 and average AUPRC of 0.40 were achieved in the external validation dataset. Fetus abnormality score, as calculated from the continuous fetal cardiotocography results, was significantly associated with actual clinical outcomes [intrauterine growth restriction: odds ratio, 3.626 (p=0.031); Apgar score 1 min: odds ratio, 9.523 (p<0.001), Apgar score 5 min: odds ratio, 11.49 (p=0.001), and fetal distress: odds ratio, 23.09 (p<0.001)].ConclusionThe machine learning model developed in this study showed precision in classifying FHR signals. This suggests that the model can be applied to medical devices as a screening tool for monitoring fetal status.
Keywords:Cardiotocography   high-risk-pregnancy   machine learning
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号