首页 | 本学科首页   官方微博 | 高级检索  
     


A three‐dimensional measurement approach for the morphology of the femoral head
Authors:Charys M. Martin  James G. Turgeon  Aashish Goela  Charles L. Rice  Timothy D. Wilson
Affiliation:1. Department of Cellular Biology & Anatomy, Medical College of Georgia, Georgia Regents University, , Augusta, GA, USA;2. Department of Anatomy & Cell Biology, Corps for Research in Instructional and Perceptual Technologies (CRIPT), Western University, , London, ON, Canada;3. Department of Medical Imaging, Western University, , London, ON, Canada;4. Faculty of Health Sciences, School of Kinesiology, Western University, , London, ON, Canada
Abstract:The hip joint is one of the most frequent sites of osteoarthritis. Advances in diagnosis and clinical treatment have progressed dramatically in the last few decades; however, there are limitations associated with the lack of reliable measures for quantifying hip joint morphology. Current diagnostic measures of the hip are performed with pre-determined measures, typically lengths and angles, on 2D radiographic planes. The current measurement techniques do not utilize the inherent 3D nature of CT and MR imaging and do not necessarily quantify the relevant clinical pathologies. A valid and reliable measurement modality that measures the surface geometry of the femoral head is necessary for early diagnosis and treatment of hip disease. The purpose of this study was to establish a method to quantify femoral head morphology using a three-dimensional model. A novel measurement approach was applied to 45 cadaveric femurs (23 right; 22 left; nine female, 17 male) and their digitally reconstructed 3D CT models. The mean difference between the cadaveric and digital measures was −2.04 mm with 95% confidence limits (CI) of 13.67 mm and −17.75 mm, respectively. The digital measurement approach was found to have excellent intraobserver reliability (ICC = 0.99, CI 0.98–0.99) and interobserver reliability (ICC = 0.98, CI 0.93–0.99). This valid and reliable novel digital measurement approach enables quantification of the 3D surface geometry of the femoral head and is able to measure individual variations and potentially detect abnormalities. This method may be used to assist future studies to establish valid diagnostic measurements for femoral head and head–neck junction pathologies.
Keywords:cadaveric  hip joint  Mimics  morphology  morphometrics  reliability  three‐dimensional  validity
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号