首页 | 本学科首页   官方微博 | 高级检索  
     


Bioprosthetic Aortic Valve Leaflet Thickening in the Evolut Low Risk Sub-Study
Affiliation:1. Center for Heart Valve Innovation, St. Paul’s Hospital, University of British Columbia, Vancouver, British Columbia, Canada;2. Department of Interventional Cardiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts;3. Department of Interventional Cardiology, OhioHealth Riverside Methodist Hospital, Columbus, Ohio;4. Department of Cardiac Surgery, University of Michigan Health System–University Hospital, Ann Arbor, Michigan;5. Departments of Thoracic Surgery and Interventional Cardiology, UPMC Pinnacle, Harrisburg, Pennsylvania;6. Department of Cardiothoracic Surgery, Winchester Medical Center, Winchester, Virginia;7. Department of Cardiology, Methodist DeBakey Heart and Vascular Center, Houston, Texas;8. Departments of Thoracic Surgery and Interventional Cardiology, Minneapolis Heart Institute, Abbott Northwestern Hospital, Minneapolis, Minnesota;9. Departments of Cardiac Surgery and Interventional Cardiology, Piedmont Atlanta Hospital, Atlanta, Georgia;10. Departments of Cardiac Surgery and Interventional Cardiology, Massachusetts General Hospital, Boston, Massachusetts;11. Department of Statistics, Medtronic, Minneapolis, Minnesota;12. Department of Cardiothoracic Surgery, Methodist DeBakey Heart and Vascular Center, Houston, Texas
Abstract:BackgroundSubclinical leaflet thrombosis has been reported after bioprosthetic aortic valve replacement, characterized using 4-dimensional computed tomographic imaging by hypoattenuated leaflet thickening (HALT) and reduced leaflet motion (RLM). The incidence and clinical implications of these findings remain unclear.ObjectivesThe aim of this study was to determine the frequency, predictors, and hemodynamic and clinical correlates of HALT and RLM after aortic bioprosthetic replacement.MethodsA prospective subset of patients not on oral anticoagulation enrolled in the Evolut Low Risk randomized trial underwent computed tomographic imaging 30 days and 1 year after transcatheter aortic valve replacement (TAVR) or surgery. The primary endpoint was the frequency of HALT at 30 days and 1 year, analyzed by an independent core laboratory using standardized definitions. Secondary endpoints included RLM, mean aortic gradient, and clinical events at 30 days and 1 year.ResultsAt 30 days, the frequency of HALT was 31 of 179 (17.3%) for TAVR and 23 of 139 (16.5%) for surgery; the frequency of RLM was 23 of 157 (14.6%) for TAVR and 19 of 133 (14.3%) for surgery. At 1 year, the frequency of HALT was 47 of 152 (30.9%) for TAVR and 33 of 116 (28.4%) for surgery; the frequency of RLM was 45 of 145 (31.0%) for TAVR and 30 of 111 (27.0%) for surgery. Aortic valve hemodynamic status was not influenced by the presence or severity of HALT or RLM at either time point. The rates of HALT and RLM were similar after the implantation of supra-annular, self-expanding transcatheter, or surgical bioprostheses.ConclusionsThe presence of computed tomographic imaging abnormalities of aortic bioprostheses were frequent but dynamic in the first year after self-expanding transcatheter and surgical aortic valve replacement, but these findings did not correlate with aortic valve hemodynamic status after aortic valve replacement in patients at low risk for surgery. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283)
Keywords:aortic stenosis  aortic valve replacement  hypoattenuated leaflet thickening  leaflet thrombosis  4D"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0035"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  4-dimensional  CT"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0045"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  computed tomographic  HALT"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0055"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  hypoattenuated leaflet thickening  LTI"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0065"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  leaflet thickening or immobility  OAC"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0075"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  oral anticoagulation  RLM"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0085"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  reduced leaflet motion  TAVR"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0095"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  transcatheter aortic valve replacement
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号