首页 | 本学科首页   官方微博 | 高级检索  
     

电感耦合等离子体质谱法测定左氧氟沙星片中8种元素杂质的含量
引用本文:孙滨滨,黄祝刚,李亚囡,唐彬,孟亚楠. 电感耦合等离子体质谱法测定左氧氟沙星片中8种元素杂质的含量[J]. 药学服务与研究, 2021, 0(1): 19-22,51
作者姓名:孙滨滨  黄祝刚  李亚囡  唐彬  孟亚楠
作者单位:山东齐都药业有限公司药物分析研究室
摘    要:目的:建立电感耦合等离子体质谱(ICP-MS)法测定左氧氟沙星片中钒(V)、铁(Fe)、钴(Co)、镍(Ni)、砷(As)、镉(Cd)、汞(Hg)、铅(Pb)8种元素杂质的含量.方法:取左氧氟沙星片剂研磨成粉,用微波消解法进行处理.采用ICP-MS法进行方法学验证及样品检测,测定模式为He模式,等离子体模式为通用模式,...

关 键 词:左氧氟沙星片  元素杂质  含量测定  电感耦合等离子体质谱仪

Content determination of 8 elemental impurities in levofloxacin tablets by inductively coupled plasma mass spectrometry method
SUN Binbin,HUANG Zhugang,LI Yanan,TANG Bin,MENG Yanan. Content determination of 8 elemental impurities in levofloxacin tablets by inductively coupled plasma mass spectrometry method[J]. Pharmaceutical Care and Research, 2021, 0(1): 19-22,51
Authors:SUN Binbin  HUANG Zhugang  LI Yanan  TANG Bin  MENG Yanan
Affiliation:(Department of Pharmaceutical Analysis,Shandong Qidu Pharmaceutical Co.,Ltd.,Shangdong Zibo 255400,China)
Abstract:Objective:To establish an inductively coupled plasma mass spectrometry(ICP-MS)for content determination of 8 elemental impurities(V,Fe,Co,Ni,As,Cd,Hg,Pb)in levofloxacin tablets.Methods:The levofloxacin tablets were ground into powder and treated by microwave digestion.ICP-MS method was used for methodological validation and sample detection.The measurement mode was He mode,and the plasma mode was general purpose mode.The sampling depth was 10.0 mm.The nebulizer gas flow was 1.03 L/min.The auxiliary gas flow was 0.90 L/min.The plasma gas flow was 15.0 L/min.The nebulizer pump speed was 0.10 r/min,and the temperature of atomizer chamber was 2℃.Results:Regression coefficients of the standard curves of eight elemental impurities were all more than 0.9990.The limits of detection and quantitation were all less than 10%of the limit concentration.The average recovery rates were within the range of 94.18%-100.75%,and RSD<5%(n=9).In repeatability,RSD<1%(n=6).The contents of 8 elemental impurities in 1 batch of reference preparation and 3 batches of test products all met the specified requirements.Conclusion:The established method for the determination of 8 elemental impurities in levofloxacin tablets has high sensitivity,accuracy and repeatability.It could be used for the control of the elemental impurities in levofloxacin tablets.
Keywords:levofloxacin tablet  elemental impurity  content determination  inductively coupled plasma mass spectrometer
本文献已被 维普 等数据库收录!