首页 | 本学科首页   官方微博 | 高级检索  
检索        


Temperature measurement and control system for transtibial prostheses: Single subject clinical evaluation
Authors:Kamiar Ghoseiri  Yong Ping Zheng  Aaron KL Leung  Mehdi Rahgozar  Gholamreza Aminian  Mehdi Masoumi
Institution:1. Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Hamadan University of Medical Sciences, Hamadan, Iran;2. Interdisciplinary Division of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Kowloon, Hong Kong;3. Department of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran;4. Interdisciplinary Division of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Kowloon, Hong Kong;5. Department of Biostatistics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran;6. Department of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran;7. Janbazan Medical and Engineering Research Center (JMERC), Tehran, Iran
Abstract:The snug fit of a prosthetic socket over the residual limb can disturb thermal balance and put skin integrity in jeopardy by providing an unpleasant and infectious environment. The prototype of a temperature measurement and control (TM&C) system was previously introduced to resolve thermal problems related to prostheses. This study evaluates its clinical application in a setting with reversal, single subject design. The TM&C system was installed on a fabricated prosthetic socket of a man with unilateral transtibial amputation. Skin temperature of the residual limb without prosthesis at baseline and with prosthesis during rest and walking was evaluated. The thermal sense and thermal comfort of the participant were also evaluated. The results showed different skin temperature around the residual limb with a temperature decrease tendency from proximal to distal. The TM&C system decreased skin temperature rise after prosthesis wearing. The same situation occurred during walking, but the thermal power of the TM&C system was insufficient to overcome heat build-up in some regions of the residual limb. The participant reported no significant change of thermal sense and thermal comfort. Further investigations are warranted to examine thermography pattern of the residual limb, thermal sense, and thermal comfort in people with amputation.
Keywords:perspiration  prosthetic socket  residual limb  skin  temperature control  temperature measurement  thermoregulatory system  transtibial amputation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号