首页 | 本学科首页   官方微博 | 高级检索  
     


Timing algorithm for bolus chase MR digital subtraction angiography
Authors:Yi Wang  Howard M. Lee  Rosalynn Avakian  Priscilla A. Winchester  Neil M. Khilnani  David Trost
Abstract:Acquire multiple longitudinal locations in the lower extremity after a single contrast injection, appropriate table translation and contrast injection are required. An approximate model based on constant bolus velocity was developed to describe the space-time course of a contrast bolus in the lower extremity. This model was verified in dynamic MR angiograms acquired in a group of patients using time-resolved 2D MR digital subtraction angiography (MRDSA). From this contrast bolus passage model, a timing algorithm for table translation and contrast injection was developed for bolus chase MRDSA, subsequently validated in bolus chase 2D MRDSA experiments. All targeted major peripheral arteries were well depicted in bolus chase 2D MRDSA using this timing algorithm and a single 15-ml contrast dose.
Keywords:bolus chase  MR digital subtraction angiography  contrast enhanced MR angiography  peripheral MR angiography