首页 | 本学科首页   官方微博 | 高级检索  
     

Moria OUP-SBK microkeratome制作LASIK角膜瓣特点及因素分析
引用本文:孙红燕,刘苏冰,聂晓丽,买志彬,辛宝莉. Moria OUP-SBK microkeratome制作LASIK角膜瓣特点及因素分析[J]. 中国实用眼科杂志, 2011, 29(11). DOI: 10.3760/cma.j.issn.l006-4443.2011.11.012
作者姓名:孙红燕  刘苏冰  聂晓丽  买志彬  辛宝莉
作者单位:1. 郑州大学第二附属医院,郑州,450002
2. 武警河南总队医院
摘    要:目的 观察LASIK术中应用Moria One Use-Plus SBK板层角膜刀制作角膜瓣的特点及相关因素.方法 LASIK手术113例(226眼)预设角膜瓣厚度为100μm.术后1周使用美国Optovue公司的RTVue-100傅立叶域光学相干断层扫描仪(OCT)测量角膜瓣厚度,与预设角膜瓣厚度进行差异性分析,与术前等效球镜,角膜直径,角膜厚度,角膜中央最大K值等进行相关性分析.结果 实际角膜瓣平均厚度为( 106.37±3.72)μm.右眼角膜瓣平均厚度为(107.17±4.28) μm,左眼角膜瓣平均厚度为(105.58±2.89)μm,两组差异有统计学意义(t=2.429,P<0.05).实际角膜瓣厚度与术前角膜中央最大K值呈正相关( RK=0.302,PK<0.05),与术前等效球镜、角膜直径、角膜厚度均无明显相关性.结论 Moria One Use-Plus SBK板层角膜刀制作角膜瓣预测性好,厚度均匀,角膜瓣厚度与术前角膜屈光力呈正相关.

关 键 词:角膜瓣  前弹力层下角膜磨镶术  相关因素  原位角膜磨镶术

Facts relating to the corneal flap creation with The Moria OUP-SBK microkeratome
SUN Hong-yan,LIU Su-bing,NIE Xiao-li,MAI Zhi-bin,XIN Bao-li. Facts relating to the corneal flap creation with The Moria OUP-SBK microkeratome[J]. Chinese Journal of Practical Ophthalmology, 2011, 29(11). DOI: 10.3760/cma.j.issn.l006-4443.2011.11.012
Authors:SUN Hong-yan  LIU Su-bing  NIE Xiao-li  MAI Zhi-bin  XIN Bao-li
Abstract:Objective To observe the flap characteristics and the facts correlating to the thickness of the cornea flap created with One Use-Plus sub-bowman's keratomileusis.Methods Two hundred and twenty-six consecutive eyes of 113 previously non-operated patients were treated with Moria OUP-SBK microkeratome.An intended flap thickness was 100 μm.One week after surgery,the flap thickness was measured by optical coherence tomography (OCT).Single variable correlations of the flap thickness and preoperative MRSE,Corneal diameter,corneal thickness,corneal keratometric value K were determined.Results The mean flap thickness was (106.37± 3.72) μm,Mean flap thickness was (107.17± 4.28) μm in right eyes and (105.58± 2.89) μm in left eyes.The difference between right and left eyes was statistically significant (t =2.429,P <0.05).Corneal flap thickness was positively correlated with preoperative corneal keratometric value K (RK=0.302,PK=0.002<0.01),but was not dependent on preoperative patient MRSE,Corneal diameter,corneal thickness.Conclusions Moria OUP-SBK microkeratome created LASIK flaps have good predictability,even thickness and are positively correlated with preoperative corneal keratometric value K.
Keywords:Corneal flap  The sub-bowman's keratomileusis  Related factors  Keratomileusis
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号