首页 | 本学科首页   官方微博 | 高级检索  
     


Breast-specific gamma imaging is a cost effective and efficacious imaging modality when compared with MRI
Authors:Nathalie Johnson  Leslie SorensonLaura Bennetts  Karen WinterSally Bryn  R.N.  William JohnsonMargie Glissmeyer  P.A.-C.  Jennifer GarreauDeb Blanchard  M.D.
Affiliation:Legacy Cancer Institute and Legacy Breast Health Center, Good Samaritan Breast Health Center, 1040 NW 22nd Avenue, Portland, OR 97210, USA
Abstract:

Background

Both MRI and breast-specific gamma imaging are tools for surgical planning in newly diagnosed breast cancer. Breast-specific gamma imaging (BSGI) is used less frequently although it is of similar utility and lower cost. We compared the diagnostic and cost efficacy of BSGI with MRI.

Methods

Retrospective review of 1,480 BSGIs was performed in a community breast health center, 539 had a new diagnosis of cancer, 75 patients having both MRI and BSGI performed within 2 months of each other. Institutional charges for BSGI ($850) and MRI ($3,381) were noted.

Results

BSGI had a sensitivity of 92%, specificity of 73%, positive predictive value of 78%, and negative predictive value of 90%. This compared favorably with MRI that had sensitivity of 89%, specificity 54%, positive predictive value 67%, and negative predictive value 83%. The accuracy of BSGI was higher at 82% vs MRI at 72%. Total cost of MRI imaging was $253,575 vs BSGI at $63,750.

Conclusions

BSGI is a cost-effective and accurate imaging study for further evaluation of dense breast tissue and new diagnosis of cancer.
Keywords:Breast cancer   BSGI   MRI   Imaging cost
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏