Visual acuity and endothelial cell density with respect to the graft thickness in Descemet's stripping automated endothelial keratoplasty:one year results |
| |
Authors: | Banu Torun Acar Mehmet Orcun Akdemir Suphi Acar |
| |
Affiliation: | 1Ophthalmology Clinic, Haydarpasa Numune Research and Education Hospital, Istanbul 34668, Turkey;2Department of Ophthalmology, School of Medicine, Bulent Ecevit University, Zonguldak 67600, Turkey;1Ophthalmology Clinic, Haydarpasa Numune Research and Education Hospital, Istanbul 34668, Turkey;2Department of Ophthalmology, School of Medicine, Bulent Ecevit University, Zonguldak 67600, Turkey;1Ophthalmology Clinic, Haydarpasa Numune Research and Education Hospital, Istanbul 34668, Turkey;2Department of Ophthalmology, School of Medicine, Bulent Ecevit University, Zonguldak 67600, Turkey |
| |
Abstract: |
AIMTo evaluate the visual acuity and endothelial cell density according to the thickness in Descemet''s stripping automated endothelial keratoplasty (DSAEK) one year after surgery.METHODSDSAEK patients'' data were reviewed. Thirty-seven eyes of 37 patients who underwent DSAEK for pseudophakic bullous keratopathy (PBK) were included in this study. Graft thickness was measured with optical coherence tomography (OCT) 12mo after DSAEK. Eyes were divided into 3 groups based on the graft thickness: thick (>200 µm), medium-thick (150-200 µm) and thin (<150 µm). Best corrected visual acuity (BCVA), endothelial cells density (ECD) and complications were assessed and comparisons were done between groups.RESULTSThere was no significant difference in age, sex, preoperative BCVA, or follow-up period between DSAEK groups. At postoperative 12mo, mean BCVA was 0.28±0.10 in thick graft group, 0.52±0.08 in medium-thick graft group, and 0.72±0.06 in thin graft group. Thin grafts showed better postoperative BCVA as compared with the medium-thick and thick grafts (P=0.001). Thick graft group had 1637.44±88.19-mm2, medium thick graft had 1764.50±34.28-mm2 and thin graft group had 1845.30±65.62-mm2 ECD at 12mo after the surgery. Thin graft group had better ECD at 12mo after surgery (P=0.001).CONCLUSIONThin grafts after DSAEK ensure better visual rehabilitation. Eyes with thin grafts had significantly lesser loss of ECD compared to eyes with medium-thick and thick grafts one year after surgery. |
| |
Keywords: | Corneal endothelial cell density Descemet''s stripping endothelial keratoplasty graft thickness visual acuity |
|
| 点击此处可从《国际眼科》浏览原始摘要信息 |
|
点击此处可从《国际眼科》下载免费的PDF全文 |
|