Fever after redo Nissen fundoplication with hiatal hernia repair |
| |
Authors: | Nicole E. SharpHanna Alemayehu MD Amita DesaiGeorge W. Holcomb III MD MBA Shawn D. St. Peter |
| |
Affiliation: | Department of Surgery, The Children''s Mercy Hospital and Clinics, Kansas City, Missouri |
| |
Abstract: | BackgroundFevers often arise after redo fundoplication with hiatal hernia repair. We reviewed our experience to evaluate the yield of a fever work-up in this population.MethodsWe performed a retrospective review of children undergoing redo Nissen fundoplication with hiatal hernia repair between December 2001 and September 2012. Temperatures and fever evaluations of those children receiving a mesh repair were compared with those without mesh. A fever defined as temperature ≥38.4°C.ResultsFifty one children received 46 laparoscopic, 4 open, and 1 laparoscopic converted to open procedures. Biosynthetic mesh was used in 25 children whereas 26 underwent repair without mesh. A fever occurred in 56% of those repaired with mesh compared with 23.1% without mesh (P = 0.02). A fever evaluation was conducted in 32% of those with mesh compared with 11.5% without mesh (P = 0.52). A urinary tract infection was identified in one child after mesh use and an infection was identified in two children without mesh, one pneumonia and one wound infection (P = 1). In those repaired with mesh, there was no significant difference in maximum temperature.ConclusionsFever is common after redo Nissen fundoplication with hiatal hernia repair and occurs more frequently, and with higher temperatures in those with mesh. Fever work-up in these patients is unlikely to yield an infectious source and is attributed to the extensive dissection during the redo procedure. |
| |
Keywords: | Nissen fundoplication Hiatal hernia Mesh Fever Pediatric |
本文献已被 ScienceDirect 等数据库收录! |