首页 | 本学科首页   官方微博 | 高级检索  
     


Fever after redo Nissen fundoplication with hiatal hernia repair
Authors:Nicole E. SharpHanna Alemayehu  MD  Amita DesaiGeorge W. Holcomb III  MD  MBA  Shawn D. St. Peter
Affiliation:Department of Surgery, The Children''s Mercy Hospital and Clinics, Kansas City, Missouri
Abstract:

Background

Fevers often arise after redo fundoplication with hiatal hernia repair. We reviewed our experience to evaluate the yield of a fever work-up in this population.

Methods

We performed a retrospective review of children undergoing redo Nissen fundoplication with hiatal hernia repair between December 2001 and September 2012. Temperatures and fever evaluations of those children receiving a mesh repair were compared with those without mesh. A fever defined as temperature ≥38.4°C.

Results

Fifty one children received 46 laparoscopic, 4 open, and 1 laparoscopic converted to open procedures. Biosynthetic mesh was used in 25 children whereas 26 underwent repair without mesh. A fever occurred in 56% of those repaired with mesh compared with 23.1% without mesh (P = 0.02). A fever evaluation was conducted in 32% of those with mesh compared with 11.5% without mesh (P = 0.52). A urinary tract infection was identified in one child after mesh use and an infection was identified in two children without mesh, one pneumonia and one wound infection (P = 1). In those repaired with mesh, there was no significant difference in maximum temperature.

Conclusions

Fever is common after redo Nissen fundoplication with hiatal hernia repair and occurs more frequently, and with higher temperatures in those with mesh. Fever work-up in these patients is unlikely to yield an infectious source and is attributed to the extensive dissection during the redo procedure.
Keywords:Nissen fundoplication   Hiatal hernia   Mesh   Fever   Pediatric
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号