首页 | 本学科首页   官方微博 | 高级检索  
     


Combined epidural/spinal anaesthesia for Caesarean section
Authors:G. LYONS  R. MACDONALD  B. MIKL
Affiliation:St James' University Hospital, Leeds.
Abstract:
An evaluation of a 30 gauge spinal needle in a combined epidural/spinal anaesthetic technique for Caesarean section revealed a 25% failure rate of the spinal element. In this unit, no more than 4% of spinal anaesthetics might be expected to fail. One of the reasons for the higher failure rate was that, when using the Tuohy needle as an introducer, the dura was not identified. This prompted us to compare the 'through-the-Tuohy' or needle within needle approach for combined epidural/spinal anaesthesia, with a technique that involved siting the epidural and spinal sequentially in separate spaces. One hundred women requiring elective Caesarean section under spinal anaesthesia were randomised into single or double space groups. The technique failed in 16% of through-the-needle cases, and in 4% of sequential sitings. Combined spinal/epidural anaesthesia for Caesarean section is more successful if each procedure is performed using separate spaces.
Keywords:Anaesthesia    obstetric    Anaesthetic techniques    regional    epidural    spinal