首页 | 本学科首页   官方微博 | 高级检索  
     


Accuracy of dual-energy radiographic absorptiometry of the lumbar spine: cadaver study
Authors:Ho, CP   Kim, RW   Schaffler, MB   Sartoris, DJ
Affiliation:Department of Radiology, University of California, San Diego.
Abstract:
Dual-energy radiographic absorptiometry (DRA) was used to measure the bone mineral content and area density of lumbar vertebrae (L2-L3) in 11 cadavers. These data were subsequently compared with measured ash content and density. Excellent correlation was obtained between bone mineral content measured with DRA and ash weight (r = .963, P less than .0001). The accuracy error in determining mineral content in lumbar vertebrae with DRA was about 9%. In addition, strong correlation was observed between bone mineral density measured with DRA and ash density (r = .881, P less than .0001).
Keywords:
点击此处可从《Radiology》浏览原始摘要信息
点击此处可从《Radiology》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号