首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   15篇
  免费   0篇
内科学   3篇
外科学   9篇
综合类   1篇
预防医学   2篇
  2023年   2篇
  2021年   4篇
  2020年   2篇
  2019年   1篇
  2018年   1篇
  2017年   1篇
  2016年   1篇
  2013年   1篇
  2012年   1篇
  2002年   1篇
排序方式: 共有15条查询结果,搜索用时 187 毫秒
1.
Archives of Sexual Behavior - Pre-exposure prophylaxis (PrEP) is a promising strategy to reduce HIV incidence among men who have sex with men (MSM). How and when PrEP is used could in part be...  相似文献   
2.
BACKGROUND Polyethylene(PE) particles produced by wear of the acetabular insert are thought to cause osteolysis and thereby aseptic loosening of the implant in total hip arthroplasty(THA). As highly cross-linked polyethylene(HXLPE) is presumed to give lower wear rates, in vivo studies are needed to confirm this.AIM To compare the wear of REXPOL, a HXPLE, with conventional PE within the first five years after implantation using Roentgen stereophotogrammetric analysis(RSA).METHODS Patients were randomised to receive either a HXLPE(REXPOL) or a conventional PE insert during primary THA. RSA images were obtained directly postoperative and after 6 wk, 12 wk, 6 mo, 12 mo, 24 mo and five years. Functional outcomes were assessed using the Hip Injury and Osteoarthritis Outcome Score and Harris Hip Score at baseline and five years after surgery.RESULTS The HXLPE(REXPOL) showed less wear in the latero-medial direction. Significant wear rates of conventional PE were seen in the latero-medial and center-proximal direction and in volume and corrected volume, whereas the REXPOL did not show these outcomes over time. Improvement from baseline in functional outcome did not significantly differ.CONCLUSION Total 3 D wear is less in THAs inserted with a REXPOL inlay than a conventional PE inlay after five years. This study confirms, for the first, that the REXPOL HXLPE inlay is preferred to standard PE.  相似文献   
3.
IntroductionDaily and event‐driven PrEP are both efficacious in reducing the risk for HIV infection. However, the practice of event‐driven PrEP (edPrEP) is less well studied, in particular when provided as an alternative to daily PrEP. We studied regimen preferences and switches, and sexually transmitted infection (STI) incidence.MethodsWe analysed pooled data from two prospective cohort studies among MSM: Be‐PrEP‐ared, Belgium and AMPrEP, the Netherlands. In both projects, participants could choose between daily and edPrEP at three‐monthly study visits, when they were also screened for sexually transmitted infections including hepatitis C (HCV). We assessed the proportion choosing each regimen, and the determinants of choosing edPrEP at baseline. Additionally, we compared the incidence rates (IRs) of HCV, syphilis and chlamydia or gonorrhoea between regimens using Poisson regression. The study period was from 3 August 2015 until 24 September 2018.Results and discussionWe included 571 MSM, of whom 148 (25.9%) chose edPrEP at baseline. 31.7% of participants switched regimen at least once. After 28 months, 23.5% used edPrEP. Older participants (adjusted odds ratio (aOR) = 1.38 per 10 years, 95% confidence interval (CI) = 1.15 to 1.64) and those unemployed (aOR = 1.68, 95% CI = 1.03 to 1.75) were more likely to initially choose edPrEP. IR of HCV and syphilis did not differ between regimens, but the IR of chlamydia/gonorrhoea was higher among daily users (adjusted incidence rate ratio = 1.61, 95% CI = 1.35 to 1.94).ConclusionsA quarter of participants chose edPrEP at baseline and at 28 months this proportion was similar. Although the IR of HCV and syphilis were similar in the two regimens, the lower incidence of chlamydia and gonorrhoea among edPrEP users may suggest that less frequent STI testing of this group could be considered.  相似文献   
4.
BACKGROUNDIn press-fit total hip arthroplasty (THA) ceramic-on-ceramic (CoC) bearings are a potential for overcoming the wear that is seen in ceramic-on-polyethylene (CoPE) bearings, and can lead to wear-induced osteolysis, resulting in loosening of the implant. However, CoC bearings show disadvantages as well, such as squeaking sounds and being more fragile, which can cause ceramic head or liner fracture. Because comparative long-term studies are limited, the objective of this study was to determine the long-term difference in wear, identify potential predictive factors for wear, investigate radiological findings such as osteolysis, and evaluate clinical functioning and complications between these bearings.AIMTo determine 10-year differences in wear, predictive factors for wear, and investigate radiological findings and clinical functioning between CoC and CoPE.METHODSThis observational prospective single-center cohort study with a 10-year follow-up includes a documented series of elective THAs. Primary outcome was wear measured by anteroposterior (AP) radiographs. Secondary outcomes were potential predictive factors for wear, complications during follow-up, Harris hip score (HHS), and radiological findings such as presence of radiolucency, osteolysis, atrophy, and hypertrophy around the cup. Due to the absence of wear in the CoC group, stratified analysis to identify risk factors for wear was only performed in the CoPE group by use of univariate linear regression analysis. HHS was expressed as a change from baseline and the association with bearing type was assessed by use of multivariate linear regression analysis, adjusted for potential confounders.RESULTSA total of 17 CoPE (63.0%) and 25 CoC (73.5%) cases were available for follow-up and showed a linear wear of respectively 0.130 mm/year (range 0.010; 0.350) and 0.000 mm/year (range 0.000; 0.005), which was significant (P < 0.001) between both groups. Wear always occurred in the cranial direction. Cup inclination was the only predictive factor for polyethylene (PE) wear. No dislocations, ceramic head, or liner fractures were seen. The HHS showed a mean change from baseline of 37.1 points (SD 18.5) in the CoPE group and 43.9 (SD 17.0) in the CoC group. This crude difference of 6.8 (range -5.2; 18.7) in favor of the CoC group was not significant (P = 0.26) and was not significant when adjusted for age, gender, and diagnosis either (P = 0.99). No significant differences in complications and radiological findings were seen between groups. CONCLUSIONCoC bearing shows lower wear rates compared to CoPE at 10-year follow-up with cup inclination as a predictive factor for wear and no differences in complications, HHS, and radiological findings.  相似文献   
5.
6.
IntroductionEvent‐driven pre‐exposure prophylaxis (edPrEP) with oral tenofovir disoproxil fumarate (TDF)/emtricitabine (FTC) is highly effective for preventing HIV acquisition in men who have sex with men (MSM) and is preferred over daily PrEP by some MSM. However, it is largely unknown how well MSM adhere to edPrEP. We then aimed to assess PrEP protection during CAS among MSM using edPrEP and participating in the Amsterdam PrEP demonstration project (AMPrEP).MethodsWe analysed data from participants enrolled in AMPrEP who were taking edPrEP. We measured adherence through (1) a mobile application in which sexual behaviour and PrEP‐use were recorded daily, (2) three‐monthly self‐completed questionnaires and (3) dried blood spot (DBS) samples collected around six, twelve and twenty‐four months after PrEP initiation. We assessed the proportion of days with condomless anal sex (CAS) acts that were protected by PrEP, per partner type (i.e. steady partners, known casual partners, unknown casual partners), and the proportion of three‐month periods during which PrEP was correctly used. Intracellular TFV‐diphosphate (TFV‐DP) concentrations were determined from DBS. Good adherence was defined as at least one tablet before and one tablet within 48 hours after a CAS act.ResultsBetween 11 September 2015 and 6 October 2019, 182 of 376 MSM (48.4%) used edPrEP for at least one three‐month period. Of the 8224 CAS days that were reported in the app during edPrEP‐use, we observed good protection for most CAS days involving steady partners (n = 1625/2455, 66.9%), known casual partners (n = 3216/3472, 92.6%) and unknown casual partners (n = 2074/2297, 90.3%). Men reported consistently correct PrEP‐use in 851 (81.4%) of the 1046 three‐month periods of edPrEP‐use. The median TFV‐DP concentration was 591 fmol/sample (interquartile range = 270 to 896).ConclusionsAdherence to edPrEP was high as determined from the online app and questionnaire. DBS measurements were consistent with two to three tablets per week on average.  相似文献   
7.
An eponym is a person after whom an eponymous term is named. These eponymous terms are easy shorthand in communication between surgeons. Therefore, they are often used and hard to eradicate. We discuss eponymous terms that describe anatomical features and fracture types in the knee. With these terms, an overview of the historical background of the eponym and its current clinical implication is discussed. The eponymous terms discussed are Gerdy tubercle, Pellegrini–Stieda lesion, Segond fracture, Hoffa fracture and fat pad. The meaning of the eponymous term is clarified, the biography of the namegiver given and its contemporary clinical implication discussed. Since eponymous terms are used frequently in inter-collegial discussion and literature, the meaning should be clear for everyone, since otherwise it might give room for misunderstanding.  相似文献   
8.
9.
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号