排序方式: 共有2条查询结果,搜索用时 0 毫秒
1
1.
PIERRE VULLIEMIN ALESSANDRO DEL BUFALO JURG SCHLAEPFER MARTIN FROMER LUKAS KAPPENBERGER 《Pacing and clinical electrophysiology : PACE》1994,17(8):1391-1398
Assuming that type I atrial flutter is a macroreentrant circuit, its cycle length should vary with the atrial dimensions. In order to test this hypothesis, flutter cycle length was measured while inducing atrial volume and pressure changes by postural and pharmacological means in seven patients undergoing a therapeutic programmed stimulation for type 1 atrial flutter conversion. Right atrial volume was estimated from B-mode echocardiography data. Basal values were compared with those obtained during inspiration, expiration, Valsalva maneuver, negative tilt (head down), and positive tilt (head up) with 0.8–1.6 mg p.o. nitroglycerin. The right atrial size increased slightly from 17.8 to 18.3 cm2 (P = 0.04) during the pressure load induced by negative tilt (+ 3 mmHg), with a corresponding lengthening of the flutter cycle length from 228 to 233 msec (P = 0.02). Similarly, pressure unloading of -2 mmHg by positive tilting and nitrates was accompanied by a decrease in right atrial size to 16.6 cm2 (P = 0.04), with a corresponding decrease in cycle length from 228 to 219 msec (P = 0.03). Respiratory maneuver yielded similar results with an inspiratory cycle lengthening, expiratory shortening, and further shortening during Valsalva maneuver. These experiments demonstrate a direct relation between cycle length and atrial volume in human type I atrial flutter. They underline the importance of the right heart preload and atrial size for the electrophysiological characteristics of type I atrial flutter. Beside its fundamental interest, this finding is important for the understanding of the mechanism of maintenance and therapeutic responses of this common arrhythmia. 相似文献
2.
ALESSANDRO G.A. DEL BUFALO JURG SCHLAEPFER MARTIN FROMER LUKAS KAPPENBERGER 《Pacing and clinical electrophysiology : PACE》1993,16(6):1240-1245
Efforts have been made to design electrodes that significantly reduce not only the acute and chronic stimulation thresholds, but also attenuate the early peaking phenomenon and polarization. At two voltage levels (2.7 V and 5.4 V, respectively), we evaluated the right ventricular stimulation thresholds obtained with a new, iridium oxide-coated electrode in ten patients who received a VVI pacemaker. Measurements were mode at implant and at multiple intervals for 1 year. Pulse width stimulation thresholds at implant were as follow: 0.04 ± 0.008 msec at 2.7 V, 0.03 ± 0.004 msec at 5.4 V; values at 2 weeks were 0.14 ± 0.06 msec at 2.7 V, 0.07 ± 0.025 msec at 5.4 V; values at 3 months were 0.09 ± 0.03 msec at 2.7 V, 0.05 ± 0.01 msec at 5.4 V; values at 1 year were 0.08 ± 0.02 msec at 2.7 V, 0.04 ± 0.01 msec at 5.4 V, The maximal increase of 0.11 ± 0.05 msec occurred at 2.7 V, 2 weeks after implant. Our results indicate that this new electrode provides low acute and long-term stimulation thresholds, as well as an attenuated early peaking phenomenon, being able to stimulate safely at 2.7 V even early after implant. 相似文献
1